  1. Working Pressure Limitations
    • Dynamic Pressure
      The working pressure should be limited to 60% of the dial range.
    • Static Pressure
      The working pressure, where no sharp fluctuations occur, should be limited to 90% of the dial range.

 

 

 

 

 

 