Pressure Measurement

TwitterFacebookLinkedInGoogleRSS

Home | Dial Indicating Pressure Gauges | 600/700 Series Process | Operating Specification

 

600/700 Series Process Pressure Gauges
640/740 Series Dry & 660/760 Series Liquid
Operating Specifications

 

  1. Working Pressure Limitations
    • Dynamic Pressure
      The working pressure should be limited to 60% of the dial range.
    • Static Pressure
      The working pressure, where no sharp fluctuations occur, should be limited to 90% of the dial range.

 

 

 

NOSHOK, INC. 1010 W. Bagley Road | Berea, OH 44017 | Ph 440.243.0888 | Fax 440.243.3472 | Webmaster | Site Map
©2018 NOSHOK. ALL RIGHTS RESERVED.