625 & 626 Series Intrinsically Safe Pressure Transmitters

Product Specifications

Click here to enlarge chart

SPECIFICATIONS
Output Signal 4 mA to 20 mA, 2-wire
Accuracy ± 0.25% Full scale (Best Fit Straight Line); ± 0.5% Terminal Point including the effects of linearity, hysteresis and repeatability;
± 0.125% Full scale accuracy optional
Hysteresis ≤ ± 0.1% Full scale
Repeatability ≤ ± 0.05% Full scale
Stability ≤ ± 0.2% Full scale for 1 year, non-accumulating
Pressure Ranges Standard ranges from vacuum to 60,000 psi
Proof Pressure 3.5 times Full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
2 times Full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times Full scale for 0 psi to 15,000 psi range
1.2 times Full scale for ranges 0 psi to 25,000 psi and 0 psi to 60,000 psi
Burst Pressure 4 times Full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
4 times Full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times Full scale for 0 psi to 15,000 psi range
2 times Full scale for ranges 0 psi to 25,000 psi and 0 psi to 60,000 psi
Power Supply 10 Vdc to 30 Vdc unregulated
Minimum voltage across transmitter connections is 10 Vdc
Load Limitations ≤ (VPower - 10_/0.020 Amp
Response Time ≤ 1 ms (between 10% and 90% Full scale)
Durability > 100,000,000 Full scale cycles
Adjustments ± 10% Full scale for zero and span
Temperature Ranges Compensated 32°F to 176°F (0°C to 80°C)
Zero effect is ± 0.011% Full scale/°F
Span effect is ± 0.011% Full scale/°F
Ambient -22°F to 212°F (-30°C to 100°C); -58°F to 220°F optional
Media -25°Fto 212°F (-32°C to 100°C); -58°F to 220°F optional
Storage -40°F to 212°F (-40°C to 100°C)
Wetted Materials Model 625 is 316 stainless steel for ranges up through 0 psi to 300 psi, 316
stainless steel with 17 -4PH stainless steel diaphragm for ranges 0 psi to
300 psi and higher: Model 626 is 316 stainless steel with BUNA N O-ring;
Hastello® C4 optional; Viton® O-ring optional
Housing Material 316 Stainless steel
Environmental Rating IP65 to IP67 depending upon electrical connection
Electromagnetic Rating Meets EMC norm EN61326: 1997/A1 1998 RFI, EMI and ESD protected
Electrical Rating Reverse polarity, over-voltage and short circuit protected
Shock 1000 g's according to IEC770 for mechanical shock
Vibration 20 g's according to IEC770 under resonance conditions
Hazardous Approvals Factory Mutual and Canadian Standards Association approved as indicated
ANSI/ISA-12.27.01-2003, Approved single seal
Weights Approximately 7 oz.