Home > OEM Pressure Transmitters & Transducers > 650 Series High Volume OEM Pressure Transducers > Product Specifications
650 Series High Volume OEM Pressure Transducers
Product Specifications
| SPECIFICATIONS | |
| Output Signal | 4 mA to 20 mA 2-wire, or 1 Vdc to 5 Vdc 3-wire |
| Pressure Ranges | Standard gauge ranges from 100 psig to 8000 psig |
| Proof Pressure | 2 times Full scale |
| Burst Pressure | 8 times Full scale for ranges 0 psi to 100 psi through 0 psi to 1500 psi 4 times Full scale for ranges 0 psi to 2000 psi through 0 psi to 8000 psi |
| Accuracy | ± 0.50 % Full scale (Best Fit Straight Line); ± 1% Terminal Point Includes the combined effects of linearity, hysteresis and repeatability |
| Repeatablity | ± 0.1 % Full scale |
| Stability | ± 0.2 % Full scale for 1 year, non-accumulating |
| Response Time | < 5 ms (belween 10 % and 90 % Full scale); restrictor port I.D. to dampen pulsations |
| Power Supply | 10 Vdc to 36 Vdc for 4 mA to 20 mA output and 1 Vdc to 5 Vdc outputs, unregulated; 14 Vdc to 36 Vdc for 0 Vdc to 10 Vdc output, unregulated 5 Vdc ±.5 Vdc for 0.5 Vdc to 4.5 Vdc output, unregulated |
| Load Limitations | ≤ (VPower - 10)/0.020 Amp for 4 mA to 20 mA output ≤ 5,000 Ω for 1 Vdc to 5 Vdc output ≤ 10,000 Ω for 0 Vdc to 10 Vdc output ≤ 4,500 Ω for 0.5 Vdc to 4.5 Vdc output |
| Wetted Materials | 17 -4PH stainless steel sensing diaphragm and 316 stainless steel pressure connection |
| Housing Material | PBT - fiber reinforced plastic |
| Temperature Ranges | Compensated 32°F to 176°F (0°C to 80°C) Zero effect ± 0.008 % Full scale/°F Span effect ± 0.008 % Full scale/°F Ambient -40°F to 212°F (-40°C to 100°C) Media -40°F to 257°F (-40°C to 125°C) Storage -40°F to 248°F (-40°C to 120°C) |
| Environmental Rating | IP67 for M12x1 electrical connection and Metri Pack connection; IP69K (steam jet cleaning) for cable connection |
| Electromagnetic Rating | CE compliant to EMC norm EN 61326:1997/A1 :1998 RFI, EMI and ESD protection |
| Electrical protection | Reverse polarity, over-voltage and short circuit protection |
| Shock | 500 g's per DIN EN 837 |
| Vibration | 20 g's per IEC 68-2 |
| Weight | Approximately 2.5 oz. |