Pigtail Steam Syphons

To view Datasheet in pdf format

   Pigtail (or coiled pipe) steam syphons should be used in all steam applications. Pigtail steam syphons protect the instrument from damaging effects of direct exposure to high temperature steam.
   To properly install and use a pigtail steam syphon, install the syphon in the pressure port, fill the syphon with water and install the pressure gauge. The water will fill the lower half of the coil and will act as a protective barrier between the high temperature steam and the pressure gauge.
   We recommend pigtail steam syphons for all steam applications. Available in 180° and 360° coil styles.


180°
Dimensions 1/4" NPT Steel 1/4" NPT 316 SS 1/2" NPT Steel & 316 SS
A IN 5.80 3.85 9.00
MM 147.3 97.8 228.6
B IN 2.50 2.50 4.50
MM 63.5 63.5 114.3

Model No. Size Material Rating Coil Style
1025 1/4" NPT Welded Steel, Schedule 40 500 PSI @ 400°F 180°
1050 1/2" NPT Welded Steel, Schedule 80 1097 PSI @ 400°F 180°
2025 1/4" NPT Welded 316 SS, Schedule 40 500 PSI @ 400°F 180°
2050 1/2" NPT Seamless 316 SS, Schedule 80 1967 PSI @ 100°F 180°
1525 1/4" NPT Welded Steel, Schedule 40 500 PSI @ 400°F 360°
1550 1/2" NPT Welded Steel, Schedule 80 1097 PSI @ 400°F 360°
2525 1/4" NPT Welded 316 SS, Schedule 40 500 PSI @ 400°F 360°
2550 1/2" NPT Welded 316 SS, Schedule 80 2650 PSI @ 500°F 360°