| Select A NOSHOK Transducer/Transmitter Series | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
|
|||||||||
|
|
|||||||||
| NOSHOK 200 SERIES HIGH PERFORMANCE VOLTAGE OUTPUT PRESSURE TRANSDUCERS |
|||||||||
![]() |
       Applications
|
| STOCK MODEL SPECIFICATIONS | |
|
Output Signal
|
0 Vdc to 5 Vdcm, 3 wire 0 Vdc to 10 Vdc, 3 wire 1 Vdc to 5 Vdc, 3 wire 1 Vdc to 6 Vdc, 3 wire 1 Vdc to 11 Vdc, 3 wire |
|
Pressure Ranges
|
Standard gauge ranges from vacuum to 15000 psig; Standard absolute ranges from 15 psia to 300 psia |
|
Proof Pressure
|
3 times Full Scale for ranges 0 to 5 psi through 0 to 200 psi 1.75 times Full Scale for ranges 0 to 300 psi through 0 to 10000 psi 1.5 times Full Scale for 0 to 15000 psi range |
|
Burst Pressure
|
3.8 times Full Scale for ranges 0 to 5 psi through 0 to 200 psi 4 times Full Scale for ranges 0 to 300 psi through 0 to 10000 psi 3 times Full Scale for 0 to 15000 psi range |
|
Accuracy
|
± 0.5 % Full Scale (Best Fit Straight Line); ± 0.25 % Full Scale optional (Includes the combined effects of linearity, hysteresis and repeatability) |
|
Repeatability
|
≤ ± 0.05 % Full Scale |
|
Hysteresis
|
≤ ± 0.1 % Full Scale |
|
Stability
|
≤ ± 0.2 % Full Scale per year, non- accumulating |
|
Response time
|
≤ 1 ms (between 10% to 90% Full Scale) |
|
Power supply
|
10 Vdc to 30 Vdc, 14 Vdc to 30 Vdc for 1 Vdc to 11 Vdc and 0 Vdc to 10 Vdc unregulated |
|
Load limitations
|
Load in resistance must be ≥ 5000 Ω for 0 Vdc to 5 Vdc, 1 Vdc to 5 Vdc, and 1 Vdc to 6 Vdc outputs; load in resistance must be ≥ 10000 Ω for 0 Vdc to 10 Vdc and 1 Vdc to 11 Vdc outputs |
|
Wetted materials
|
316 stainless steel for vacuum through 300 psi;17-4PH stainless steel sensing diaphragm and 316 stainless steel pressure connection for higher ranges Current consumption 8 mA |
|
Housing material
|
316 stainless steel |
|
Adjustment
|
±10 % Full Scale for zero and span |
|
Pressure cycle limit
|
150 Hz |
|
Durability
|
> 100 million cycles |
|
Temperature ranges
|
Compensated 32 °F to 176 °F (0 °C to 80 °C) Zero effect ±0.017 % Full Scale/°F Span effect ±0.017 % Full Scale/°F Ambient -40 °F to 185 °F (-40 °C to 85 °C) Media -22 °F to 212 °F (-30 °C to 100 °C) |
|
Environmental rating
|
IP65, NEMA 4X according to EN 60529/IEC 529; |
|
Electromagnetic rating
|
CE compliant to EMC norm EN 61326:1997/A1:1998 RFI, EMI and ESD protection |
|
Electrical protection
|
Reverse polarity, over-voltage and short circuit protection |
|
Shock resistance
|
1000 g’s per IEC 60770-1 |
|
Vibration resistance
|
30 g’s per IEC 60770-1 |
|
Weight
|
Approximately 3.5 oz |