Select A NOSHOK Transducer/Transmitter

SELECT SERIES


625/626
Intrinsically Safe Pressure Transducers











100 Series
Current Output Pressure Transmitter


  • 4 mA to 20 mA Output (2-wire)
  • Pressure ranges covering vacuum through 15,000 psi
  • ±0.5 % Full Scale (BFSL) accuracy standard, ±0.25 % Full Scale (BFSL) Optional


Return to the top










200 Series
Voltage Output Pressure Transducers

  • 0 Vdc to 5 Vdc output (3-Wire)
    0 Vdc to 10 Vdc output (3-Wire)
    1 Vdc to 5 Vdc output (3-Wire)
    1 Vdc to 6 Vdc output (3-Wire)
    1 Vdc to 11 Vdc output (3-Wire)
  • Pressure ranges covering vacuum through 15,000 psi
  • ±0.5 % Full Scale (BFSL) accuracy standard, ±0.25 % Full Scale (BFSL) optional






Return to the top









600 Series
Heavy Duty OEM Pressure Transducers

  • 4 mA to 20 mA output (2-Wire)
    1 Vdc to 5 Vdc output (3-Wire)
    1 Vdc to 6 Vdc output (3-wire)
    0 Vdc to 10 Vdc output (3-Wire)
  • Pressure ranges covering vacuum through 15,000 psig
  • ±0.5 % Full Scale (BFSL) accuracy







Return to the top










612 Series
Submersible Level Transducers

  • 4 mA to 20 mA output (2-Wire submersible)
    0 Vdc to 5 Vdc output (3-Wire)
    1 Vdc to 6 Vdc output (3-wire)
    0.5 Vdc to 2.5 Vdc output (3-Wire)
  • Pressure ranges covering ambient through 500 psig
  • ±0.25 % Full Scale (BFSL) accuracy standard, ±0.125 % Full Scale (BFSL) optional







Return to the top









615/616 Series
High Accuracy Heavy Duty Pressure Transducers

  • 4 mA to 20 mA output (2-Wire)
    1 Vdc to 5 Vdc output (3-wire)
    1 Vdc to 6 Vdc output (3-wire)
    1 Vdc to 11 Vdc output (3-wire)
    0 Vdc to 5 Vdc output (3-wire)
    0 Vdc to 10 Vdc output (3-Wire)
    0 Vdc to 5 Vdc output (4-Wire)
    1 Vdc to 10 Vdc output (4-Wire)
  • Pressure ranges covering vacuum through 120,000 psi
  • ±0.25 % Full Scale (BFSL) accuracy standard, ±0.125 % Full Scale (BFSL) optional







Return to the top







621 / 622 Series
Explosion Proof Pressure Transmitters

  • 4 mA to 20 mA (2-Wire)
    1 Vdc to 5 Vdc Low Power (3-wire)
    0.5 Vdc to 4.5 Vdc Low Power (3-wire)
  • Standard ranges from vacuum to 15000 psi
  • ±0.25 % Full Scale (BFSL)



Return to the top







623 / 624 Series
Non-Incendive Pressure Transmitters

  • 4 mA to 20 mA (2-Wire)
    1 Vdc to 5 Vdc Low Power (3-wire)
    0.5 Vdc to 4.5 Vdc Low Power (3-wire)
  • Standard ranges from vacuum to 15000 psi
  • ±0.25 % Full Scale (BFSL)



Return to the top









625 / 626 Series
Intrinsically Safe Pressure Transmitters

  • 4 mA to 20 mA output (2-Wire)
    intrinsically safe and Factory & Canadian Stds. Association Approved
  • Pressure ranges covering vacuum through 60,000 psi
  • ±0.25 % Full Scale (BFSL) accuracy standard, ±0.125 % Full Scale (BFSL) optional





Return to the top






627 Series
Intrinsically Safe Submerible Level Transmitters

  • 4 mA to 20 mA output (2-wire intrinsically safe submersible)
  • Pressure ranges covering vacuum through 500 psi
  • ±0.5 % Full Scale (BFSL), ±0.125 % Full Scale







Return to the top





630 Series
Hall Effect Pressure Transducers

  • 0 Vdc to 5 Vdc output (3-wire)
    0 Vdc to 10 Vdc output (3-wire)
    0 Vdc to 5 Vdc output (3-wire)
    0.5 Vdc to 4.5 Vdc output (3-wire ratio metric)
  • Pressure ranges covering vacuum through 300 psig
  • ±0.5 % Full Scale (BFSL) accuracy






Return to the top






640 Series
Precision Pressure Transducers

  • 4 mA to 20 mA output (2-wire)
    0 Vdc to 5 Vdc output (3-wire)
    0 Vdc to 10 Vdc output (3-wire)
    RS232C digital output
  • Pressure ranges covering vacuum through 15,000 psig
  • ±0.05 % Full Scale (BFSL) accuracy standard, ±0.025 % (BFSL) Full Scale optional






Return to the top






650 Series
High Volume OEM Pressure Transducer

  • 4 mA to 20 mA output (2-wire)
    1 Vdc to 5 Vdc output (3-wire)
  • Pressure ranges covering 400 psi through 8,000 psig
  • ±0.5 % Full Scale (BFSL) accuracy standard






Return to the top






660 Series
Micro-Size Pressure Transducer

  • 4 mA to 20 mA output (2-wire)
    1 Vdc to 5 Vdc output (3-wire)
    1 Vdc to 6 Vdc output (3-wire)
    0 Vdc to 10 Vdc output (3-wire)
  • Standard gauge ranges from 200 psi to 15,000 psi
  • ±0.25 % Full Scale (BSFL) accuracy standard



Return to the top






680 Series
Thick Film Pressure Transducer

  • 4 mA to 20 mA output (2-wire)
    0 Vdc to 10 Vdc output (3-wire)
    1 Vdc to 5 Vdc output (3-wire)
    0.5 Vdc to 4.5 Vdc (3-wire ratio metric to power supply)
  • Pressure ranges covering vacuum through 1,500 psig
  • ±0.5 % Full Scale (BFSL) accuracy standard






Return to the top










755 / 756 Series
Digital Pressure Transmitter
  • 4 mA to 20 mA output (2-wire)
  • Standard pressure ranges from vacuum to 15,000 psi
  • ±0.05 % Full Scale (BFSL), ±0.15 % Full Scale for ranges 0 psig to 15,000 psig






Return to the top










800 Series
Platinum Resistance Temperature Transmitter
  • 4 mA to 20 mA output (2-wire)
    0 Vdc to 10 Vdc output (3-Wire)
  • Temperature ranges covering -40 ºC to 1000 ºC
  • Class B (±0.5 % Full Scale)






Return to the top










1000 Series
Digital Pressure Gauge
  • 7-segment, Liquid Crystal Display, .5” high
  • Standard gauge ranges from vacuum to 5000 psig
  • ±0.5 % Full Scale accuracy standard






Return to the top






1800 Series
Attachable Loop-Powered Digital Indicator
  • 7-segment, Liquid Crystal Display, .4” high
  • The 4 mA to 20 mA signal from the transmitter can be assigned any display value within the display range. Both scaling points are individually adjustable using the push buttons inside the case
  • ±0.2 % Full Scale, ±1 digits


Return to the top








1900 Series
Loop Powered Digital Indicator
  • 3 1/2 digit (1999 to 1999), 0.6" tall LCD
  • 4 mA to 20 mA input signal
    10 mA to 50 mA input signal
  • Loop powered





Return to the top





2000 Series
Smart System "Intelligent" Digital Indicator
  • 4 mA to 20 mA output (2-wire)
    0 Vdc to 5 Vdc output (3-wire)
    1 Vdc to 6 Vdc output (3-wire)
    0 Vdc to 10 Vdc output (3-wire)
    1 Vdc to 11 Vdc output (3-wire)
  • ±0.03 % of reading +3 micro amps for 4 mA to 20 mA
    input; +/-0.03 % of reading +3 millivolts for 0 V dc to 5 V dc
    and 0 V dc to 10 V dc inputs over the range of 18 ºC to 28 °C


Return to the top