Replaceable

Home » Products » Diaphragm Seals » Replaceable » Type 10/10H Standard & Elevated Pressure, Bolted, Replaceable Diaphragm Seals

Type 10/10H Standard & Elevated Pressure, Bolted, Replaceable Diaphragm Seals

REQUEST A QUOTE VIEW BY PART NUMBER
Download Literature
Water/
Wastewater
  • Designed to isolate the pressure measuring instrument from high temperatures, or corrosive or viscous process media
  • Can be used for remote mounting of pressure instrument(s) with capillary, see options & accessories below
  • Utilizes a replaceable diaphragm clamped between the flanged metal housings with an o-ring seal to create a leak-free union
  • Process connection sizes from 1/4" NPT through 1-1/2" NPT
  • Flushing port connection is an available option that allows the wetted areas of the seal to be cleaned, or the process vented without removing the unit from the line
  • Consider instrument size, pressure range, media composition, ambient and operating temperature, and maximum working pressure when selecting
  • Capillaries and cooling elements are available for elevated process temperatures, see options & accessories below
  • Fill fluid must be compatible with process media; i.e. Glycerin may become volatile in conjunction with a strong oxidizing agent such as chlorine, forms of oxygen or peroxide and nitric acids

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

TYPES 10 (2,000 psi) 10H (5,000 psi)    
INSTRUMENT CONNECTION SIZES 02 1/4" NPT 04 1/2" NPT    
UPPER HOUSING MATERIALS C Carbon steel S 316 Stainless steel    
DIAPHRAGM MATERIALS A Tantalum N Inconel 600 U Titanium grade 4
H Hastelloy C-276 S 316 Stainless steel ** V FKM *, ***
M Monel 400 T PTFE *, †    
O-RING MATERIALS B NBR T PTFE1 V FKM
PROCESS CONNECTION SIZES 02 1/4" NPT 06 3/4" NPT 10 1-1/4" NPT
04 1/2" NPT 08 1" NPT 12 1-1/2" NPT
  (ASME and DIN flanges available upon request)    
LOWER HOUSING MATERIALS C Carbon steel M Monel 400 S 316 Stainless steel
H Hastelloy C-276 N Inconel 600 U Titanium
FLUSHING CONNECTIONS 1F 1/8" NPT 2F 1/4" NPT    

* Not available on 10H
** NBR o-rings standard with 316SS diaphragm
*** FKM o-rings standard with FKM diaphragm
† PTFE o-rings standard with all other diaphragms

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

PRODUCT SPECIFICATIONS
Seal type Threaded with replaceable diaphragm. Flanged available on request.
Instruments Type Size Minimum Pressure Maximum Pressure
Gauges 2-1/2" to 6" 0 psig to 30 psig 0 psig to 2,000 psig (10H - 5,000 psig)
Transducers - 0 psig to 30 psig 0 psig to 2,000 psig (10H - 5,000 psig)
Switches - 0 psig to 30 psig 0 psig to 2,000 psig (10H - 5,000 psig)
Upper housing Type Non-continuous duty (10H continuous duty)
Connections 1/4" NPT, 1/2" NPT
Materials Polyurethane enamel coated steel, 316 Stainless Steel
Diaphragm Size 3.0" (Type 10), 2-1/2" (Type10 H)
Displacement 3.2 ml (Type 10), 1.4 ml (Type 10H)
Materials 316 Stainless Steel (Exotic materials available on request)
O-rings   NBR, PTFE and FKM
Lower housing Connections 1/4" NPT, 1/2" NPT, 3/4" NPT, 1" NPT, 1-1/4" NPT, 1-1/2" NPT
ASME flanges available on request
Materials Polyurethane enamel coated steel and 316 Stainless Steel (Exotic materials available on request)
Flushing port Optional 1/8" NPT, 1/4" NPT and dual ports
Bolting   Zinc-plated steel, optional Stainless Steel
Operating temperature   Operating temperature is determined by the temperature/pressure configuration.
See Material temperature table.

Options & Accessories

  • 1/4" NPT X 1/4" NPT Cooling Element (1/4" NPT X 1/4" NPT-CE)
  • 1/2" NPT X 1/2" NPT Cooling Element (1/2" NPT X 1/2" NPT-CE)
  • Works in combination with diaphragm seal to isolate instrument from high media temperatures
  • Recommended for process temperatures above 212 °F
  • Requires direct mounted system
  • Effective temperature reductions of 200 °F depending upon ambient conditions
  • High >212 °F process temperature, low < -40 °F process temperature
  • All Stainless Steel construction

WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

  • Glycerin (GY) *
  • Silicone (SL)
  • Halocarbon® (HL)
  • Neobee M20 (NB)
  • Mineral Oil (MO)
  • Propylene Glycol (PG)

* Not recommended for use in vacuum applications.

NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths.

View NOSHOK Distribution Manifolds

  • 5 ft. SS Armored Flexible Capillary, 1/4" NPT (AC-02-02-5) per ft. adder (AC-02-02-#)
  • 5 ft. SS Armored Flexible Capillary, 1/2" NPT (AC-04-04-5) per ft. adder (AC-04-04-#)
  • Stainless Steel capillaries available with or without Stainless Steel armor
  • Protects the instrument from high or low process temperatures
  • Allows remote mounting of pressure instrument(s)
  • Select the shortest capillary length possible, as changes in ambient temperature conditions may significantly affect the accuracy and response time of the instrument
  • Standard length 5', others available
  • Installation on analog gauges requires a gauge support and gauge adaptor, or other surface mounting provisions
  • Any level difference between the instrument and the seal will result in a pressure indication error; make sure to compensate for the level difference during calibration of the diaphragm seal assembly if the level difference is known
  • Filling options for capillaries
    • Silicone - specify to 10 or 20 feet (SL-C)
    • Halocarbon® - specify to 10 or 20 feet (HL-C)

WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov


WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

WARNING:This product can expose you to chemicals including Lead and Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov