Use the PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to the new PT Series transmitters.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SERIES | 613 | |||||||
PRESSURE RANGES | 5 | 0 psi to 5 psi (11.55 ft/H2O) | 20 | 0 psi to 20 psi (46.20 ft/H2O) | 75 | 0 psig to 75 psig (173.25 ftH2O) | 300 | 0 psig to 300 psig (693 ft/H2O) |
10 | 0 psi to 10 psi (23.10 ft/H2O) | 30 | 0 psi to 30 psi (69.30 ft/H2O) | 100 | 0 psig to 100 psig (231.00 ft/H2O) | |||
15 | 0 psi to 15 psi (34.65 ft/H2O) | 50 | 0 psig to 50 psig (115.5 ft/H2O) | 150 | 0 psig to 150 psig (346.50 ft/H2O) | |||
ACCURACIES | 1 | ± 0.25% full scale (BFSL) | 2 | ± 0.125% full scale (BFSL) | ||||
OUTPUT SIGNALS | 1 | 4 mA to 20 mA, 2-wire | 5 | 0 Vdc to 10 Vdc, 3-wire | ||||
2 | 0 Vdc to 5 Vdc, 3-wire | 11 | 0.5 Vdc to 2.5 Vdc, 3-wire | |||||
ELECTRICAL CONNECTIONS |
XX | Standard polyurethane (PUR) cable | 38-XX | FEP cable | ||||
NOTE: XX = length of cable in feet | ||||||||
OPTIONS | CBC | Cable Clamp | FE | Filter Element | LP | Lightning Protection* | PT1 | PT100RTD* |
DC | Desiccant Cartridge | JB | Cable Junction Box | LR | Lifting Ring |
* Only available with PUR cable
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SPECIFICATIONS | |
Output signals | 4 mA to 20 mA, 2-wire; 0 Vdc to 5 Vdc and 0 Vdc to 10 Vdc, 3-wire; 0.5 Vdc to 2.5 Vdc, 3-wire |
Pressure ranges | 0 psi to 5 psi through 0 psi to 300 psi |
Accuracy | ± 0.25% full scale (BFSL); optional ± 0.125% full scale (BFSL); (includes the effects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors) |
Stability | ≤ ± 0.2% full scale for 1 year, non-accumulating |
Response time | ≤ 1 ms (between 10% and 90% full scale) |
Service life | > 100,000,000 load cycles |
Temperature measurement | Optional PT100, 4-wire per IEC 60751 |
Temperature ranges | Compensated 32 °F to 122 °F/0 °C to 50 °C Effect ± 0.01%/ °F for zero and span Media 14 °F to 122 °F / -10 °C to 50 °C Storage -22 °F to 175 °F/ -30 °C to 80 °C |
Power requirement* | 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 0 Vdc to 5 Vdc, 3-wire) 5 Vdc to 30 Vdc (0.5 Vdc to 2.5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
Load limitations | ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA ≥ 10,000 Ω for 0 Vdc to 10 Vdc, 3-wire ≥ 5,000 Ω for 0 Vdc to 5 Vdc, 3-wire |
Proof pressure | 2 times range |
Burst pressure | 4 times range |
Measuring element | Cage seal: All 316 stainless steel Cable: polyurethane, optional FEP |
Connection | 316 stainless steel |
Housing material | 316 stainless steel |
Environmental rating | IP68 |
Electromagnetic rating | CE compliant to EMC norm EN 61326:2014/A1:1998 RFI, EMI and ESD protection |
Electrical protection | Reverse polarity protection, short circuit and optional lightning protection per EN 6100-4-5; 1.5J |
Shock | 100 g’s according to IEC 60068-2-27 |
Vibration | 15 g’s according to IEC 60068-2-6 |
Weight | Approximately 3.2 lb. - cable extra |
* Only available with PUR cable
WARNING:This product can expose you to chemicals including Lead and Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov