ORDERING INFORMATION
| DIAL SIZES | 20 | 2" (Back connected only) | 30 | 3" | 50 | 5" |
| CASE TYPES | 300 | Bottom connection | 310 | Back connection | 320 | Adjustable angle connection** |
| STEM LENGTHS | 025 | 2-1/2" | 120 | 12" | 300 | 30" |
| 040 | 4" | 150 | 15" | 360 | 36" | |
| 060 | 6" | 180 | 18" | 420 | 42" | |
| 090 | 9" | 240 | 24" | Available up to 120" | ||
| TEMPERATURE RANGES Dual Scale °F/°C |
-100/100 F/C | -100 °F/C to 100 °F/C | 0/250 F/C | 0 °F/C to 250 °F/C | 50/500 F/C | 50 °F/C to 500 °F/C |
| -40/160 F/C | -40 °F/C to 160 °F/C | 20/240 F/C | 20 °F/C to 240 °F/C | 150/750 F/C | 150 °F/C to 750 °F/C | |
| 0/140 F/C | 0 °F/C to 140 °F/C | 25/125 F/C | 25 °F/C to 125 °F/C† | 200/1000 F/C | 200 °F/C to 1,000 °F/C* | |
| 0/180 F/C | 0 °F/C to 180 °F/C | 50/300 F/C | 50 °F/C to 300 °F/C | |||
| 0/220 F/C | 0 °F/C to 220 °F/C | 50/400 F/C | 50 °F/C to 400 °F/C | |||
| Single Scale °F | -100/100 F | -100 °F to 100 °F | 0/300 F | 0 °F to 300 °F** | 50/550 F | 50 °F to 550 °F |
| -50/120 F | -50 °F to 120 °F | 0/500 F | 0 °F to 500 °F** | 100/800 F | 100 °F to 800 °F** | |
| -40/160 F | -40 °F to 160 °F | 20/240 F | 20 °F to 240 °F | 150/750 F | 150 °F to 750 °F | |
| 0/140 F | 0 °F to 140 °F | 25/125 F | 25 °F to 125 °F | 200/1000 F | 200 °F to 1,000 °F* | |
| 0/180 F | 0 °F to 180 °F | 50/250 F | 50 °F to 250 °F | |||
| 0/200 F | 0 °F to 200 °F | 50/300 F | 50 °F to 300 °F | |||
| 0/220 F | 0 °F to 220 °F | 50/400 F | 50 °F to 400 °F | |||
| 0/250 F | 0 °F to 250 °F | 50/500 F | 50 °F to 500 °F | |||
| Single Scale °C | -75/175 C | -75 °C to 175 °C | 0/50 C | 0 °C to 50 °C | 0/300 C | 0 °C to 300 °C |
| -70/70 C | -70 °C to 70 °C** | 0/60 C | 0 °C to 60 °C** | 0/400 C | 0 °C to 400 °C | |
| -50/100 C | -50 °C to 100 °C** | 0/80 C | 0 °C to 80 °C** | 0/450 C | 0 °C to 450 °C | |
| -50/50 C | -50 °C to 50 °C | 0/100 C | 0 °C to 100 °C | 100/400 C | 100 °C to 400 °C | |
| -30/50 C | -30 °C to 50 °C | 0/150 C | 0 °C to 150 °C | 100/550 C | 100 °C to 550 °C* | |
| -40/70 C | -40 °C to 70 °C | 0/200 C | 0 °C to 200 °C | |||
| -20/120 C | -20 °C to 120 °C** | 0/250 C | 0 °C to 250 °C | |||
| -10/110 C | -10 °C to 110 °C** | |||||
| Consult factory for additional temperature ranges | ||||||
| OPTIONS | 6 | 6 mm stem diameter** | HD | Heavy-Duty Stem (0.375" Dia.)** | SD | Safety Glass Lens** |
| 8 | 8 mm stem diameter** | LL | Polycarbonate Lens | SL | Silicone Filled ††† | |
| 316 | 316 SS Connection & Stem** | MIP | Maximum Indicating Pointer*** | ST | Stainless Steel Tagging | |
| AU | 1/2" NPT Adjustable Union** | MIP2 | Min and Max Indicating Pointers*** | TG | Tempered Glass Lens†† | |
| GD | Glow Dial† | PL | Acrylic Lens | |||
Note: All 316 Stainless Steel construction (case, bezel, wetted parts) is available. Please consult factory.
* Thermometers with temperature ranges 200/1000 °F and 100/500 °C are not recommended for continuous use above 800 °F/425 °C. For intermittent use only.
** Available for 3" and 5" dial sizes only.
*** Available only on 30-310 and 50-310 models.
† Available only on 50-320 model. Includes reflective pointer and two reflective clips.
†† Only available with 3" dial size and without silicone filling (-SL).
††† Available only for ranges from -50 °F (-45 °C) to 500 °F (260 °C). Polycarbonate lens is standard with Silicone Fill.
ORDERING INFORMATION - SANITARY TRI-CLAMP
| DIAL SIZES | 30 | 3" | 50 | 5" | ||
| CASE TYPES | 300 | Bottom connection | 310 | Back connection | 320 | Adjustable angle connection |
| STEM LENGTHS | 01625 | 1.625" | 045 | 4.5" | 135 | 13.5" |
| 025 | 2.5" | 075 | 7.5" | 165 | 16.5" | |
| 0275 | 2.75" | 105 | 10.5" | 225 | 22.5" | |
| TEMPERATURE RANGES Dual Scale °F/°C |
0/220 F/C | 0 °F/°C to 220 °F/°C | 20/240 F/C/C | 20 °F/°C to 240 °F/°C | ||
| 0/250 F/C | 0 °F/°C to 250 °F/°C | 50/300 F/C | 50 °F/°C to 300 °F/°C | |||
| Single Scale °F | -40/160 F | -40 °F to 160 °F | 0/250 F | 0 °F to 250 °F | 50/300 | 50 °F to 300 °F |
| 0/140 F | 0 °F to 140 °F | 0/300 F | 0 °F to 300 °F | |||
| 0/220 F | 0 °F to 220 °F | 20/240 F | 20 °F to 240 °F | |||
| Single Scale °C | -20/120 C | -20 °C to 120 °C | 0/100 C | 0 °C to 100 °C | ||
| -10/110 C | -10 °C to 110 °C | 0/150 C | 0 °C to 150 °C | |||
| PROCESS CONNECTIONS | 06SAN | 3/4" Sanitary Tri-Clamp® | 16SAN | 2" Sanitary Tri-Clamp® | 24SAN | " Sanitary Tri-Clamp® |
| 12SAN | 1-1/2" Sanitary Tri-Clamp® | 20SAN | 2-1/2" Sanitary Tri-Clamp® | 32SAN | 4" Sanitary Tri-Clamp® |
Note: Most standard bimetal thermometer options are available with Sanitary Tri-Clamp connection, consult factory.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
| MODELS | SPECIFICATIONS | |
| Case & Bezel | All 300 Series | 304 Stainless Steel |
| Lens | All 300 Series | Instrument glass |
| Pointer | All 300 Series | Aluminum, black finished |
| Stem diameter | 300 Series,Standard & 06SAN | 0.250" (6.35 mm) |
| 300 Series, All Other Sanitary models | 0.375" (9.53 mm) | |
| Accuracy | All 300 Series | ±1% full scale, Grade A, ASME B40.3 |
| Dial | All 300 Series | Anodized Aluminum with large black numbers and graduations |
| Process connection | 300 Series, 2" Dial Size, Standard | 1/4" NPT |
| 300 Series, 3" & 5" Dial Size, Standard | 1/2" NPT | |
| 300 Series, Sanitary | 3/4" Tri-Clamp through 4" Tri-Clamp | |
| Wetted parts | 300 Series, Standard | 304 Stainless Steel; 316 Stainless Steel optional |
| 300 Series, Sanitary | 316 Stainless Steel | |
| Hermetic seal | All 300 Series | Per ASME B40.3 dustproof and leakproof |
| Bimetal coil | All 300 Series | Silicone coated helix coil on ranges below 500 °F for vibration dampening, maximum heat transfer and response time |
| Over temperature limits | All 300 Series | Up to 250 °F 100%; 250 °F to 500 °F 50%; 550 °F to 1,000 °F continuous use up to 800 °F; intermittent use over 800 °F |
| Recalibrator | All 300 Series | External reset |
| Adjustable angle form |
320 Series | All Stainless Steel brackets with screws that loosen to allow 360° rotation of head and 180 ° adjustment of stem position |

WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.

WARNING:This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
A: Maximum temperature for a bi-metal thermometer in continuous use is 800 ∞F but it can be used in applications intermittently up to 1000 ∞F.
A: RTDs, or resistance temperature devices, are temperature sensors that are commonly used in a variety of industrial applications including industrial boilers, petrochemical, exhaust gas monitoring and food processing. RTD sensors have a higher accuracy than thermocouples and thermistors over a wide temperature range, and are more stable over time. Simply put, an RTD is a sensor whose resistance changes with temperature in a consistent repeatable manner.
A: An RTD can provide highly accurate and consistent temperature measurements because the change in resistance of certain materials is so predictable. Most RTD sensors have a response time between 0.5 to 5 seconds and commonly feature a platinum-based element, but can also be constructed with nickel or copper. RTDs made with platinum, also known as PRTs or platinum resistance thermometers, are used most often today due to their higher temperature capabilities, better stability and repeatability. Probe type RTDs generally consist of a rigid probe with direct mounted connector or extension cable. Assembly type models usually incorporate a rigid probe assembled with a connection head or junction box. Direct immersion probes have the RTD protective sheath, the probe, welded to a process fitting similar to temperature gauges, which offers better response but limited mechanical protection and limited access to a process under operation. Assemblies for thermowells have the RTD probe typically spring loaded in the connection fitting, which ensures good thermal contact and removes dead space in the well tip.
A: An RTD connection head provides a clean, protected area for mounting a terminal block or transmitter, and can be rated for indoor or outdoor use, providing protection against dust, rain, splashing and water from washdown hoses. NOSHOK RTD connection heads are available in cast aluminum, white polypropylene and cast 316 stainless steel. White polypropylene is popular for sanitary and chemical applications, while stainless steel is often used in food, pharmaceutical, biotech and chemical applications. Aluminum and stainless steel are preferred for industrial applications. Intrinsically safe explosion-proof enclosures are also available for hazardous environments.
A: The physical principles of vapor actuation require that the dial face be printed with a nonlinear, progressively graduated temperature scale. These instruments are available for direct mounting, or for remote mounting with capillary lengths up to 100 feet. Sensing bulb length is dependent upon the capillary length selected; a longer capillary length will require a longer sensing bulb length.
A: A thermowell would offer additional protection and is the preferred method if the application allows for one to be installed.
A: The sliding compression fitting can be used to adjust the immersion depth of the instrument's stem. The adjustable union connection can be used to reposition the dial face for better viewing.
A: A thermowell is used with a temperature-sensing instrument to provide a protective barrier between the instrument and the process media. Thermowells can provide protection from harmful process influences including flow, high pressure and harsh environments, reducing the possibility of damage to the temperature instrument and providing protection to the operator. Thermowells also allow easier service to the instrument and reduce operating costs by allowing the temperature instrument to be removed and replaced without shutting down and draining the process.
A: The most commonly used types of thermowells are threaded, socket weld, weld-in and flanged connections. A threaded thermowell is screwed directly into the process through the tapped pipe wall or via a thermowell threadolet. Socket weld thermowells can be welded directly into the socket of the weldolet or into the wall of the pipe. Weld-in thermowells are welded directly into the piping or a process vessel. Flanged thermowells incorporate a flange collar located on the mating flange, which is paired with a pipe nozzle.
A: A lagging extension, often referred to as the thermowell's T length, is located on the cold side of the process connection and is usually an extension of the hex length of the thermowell. The lagging extension enables the probe and thermowell to extend through insulation or walls.
A: The bore depth S of a thermowell can be used as a reference for the maximum stem length. The S must equal or exceed the length of the sensitive portion of the instrument's stem.
More questions? Contact NOSHOK Customer Support at info@noshok.com