Use the PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to the new PT Series transmitters.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
| SERIES | PTI10 | |||||
| PRESSURE RANGES |
1barv | -1 barg to 0 barg (-14.5 psig to 0 psig) |
2.5barg | 0 barg to 2.5 barg (0 psig to 36.3 psig) |
600barg | 0 barg to 600 barg (0 psig to 8700 psig) |
| .6barc | -1 barg to 0.6 barg (-14.5 psig to 8.7 psig) |
4barg | 0 barg to 4 barg (0 psig to 58 psig) |
1000barg | 0 barg to 1000 barg (0 psig to 14500 psig) |
|
| 1.5barc | -1 barg to 1.5 barg (-14.5 psig to 21.8 psig) |
6barg | 0 barg to 6 barg (0 psig to 87 psig) |
.4bara | 0 bara to 0.4 bara (0 psia to 5.8 psia) |
|
| 3barc | -1 barg to 3 barg (-14.5 psig to 43.5 psig) |
10barg | 0 barg to 10 barg (0 psig to 145 psig) |
.6bara | 0 bara to 0.6 bara (0 psia to 8.7 psia) |
|
| 5barc | -1 barg to 5 barg (-14.5 psig to 72.5 psig) |
16barg | 0 barg to 16 barg (0 psig to 232 psig) |
1bara | 0 bara to 1 bara (0 psia to 14.5 psia) |
|
| 9barc | -1 barg to 9 barg (-14.5 psig to 130.5 psig) |
25barg | 0 barg to 25 barg (0 psig to 362.5 psig) |
1.6bara | 0 bara to 1.6 bara (0 psia to 23.2 psia) |
|
| 15barc | -1 barg to 15 barg (-14.5 psig to 217.5 psig) |
40barg | 0 barg to 40 barg (0 psig to 580 psig) |
2.5bara | 0 bara to 2.5 bara (0 psia to 36.3 psia) |
|
| 24barc | -1 barg to 24 barg (-14.5 psig to 348 psig) |
60barg | 0 barg to 60 barg (0 psig to 870 psig) |
4bara | 0 bara to 4 bara (0 psia to 58 psia) |
|
| .4barg | 0 barg to 0.4 barg (0 psig to 5.8 psig) |
100barg | 0 barg to 100 barg (0 psig to 1450 psig) |
6bara | 0 bara to 6 bara (0 psia to 87 psia) |
|
| .6barg | 0 barg to 0.6 barg (0 psig to 8.7 psig) |
160barg | 0 barg to 160 barg (0 psig to 2320 psig) |
10bara | 0 bara to 10 bara (0 psia to 145 psia) |
|
| 1barg | 0 barg to 1 barg (0 psig to 14.5 psig) |
250barg | 0 barg to 250 barg (0 psig to 3625 psig) |
16bara | 0 bara to 16 bara (0 psia to 232 psia) |
|
| 1.6barg | 0 barg to 1.6 barg (0 psig to 23.2 psig) |
400barg | 0 barg to 400 barg (0 psig to 5800 psig) |
25bara | 0 bara to 25 bara (0 psia to 362.5 psia)) |
|
| barv = vacuum gauge pressure barc = compound gauge pressure barg = gauge pressure bara = absolute pressure Other ranges available on request |
||||||
| ACCURACY | 1 | 1.0% full scale | 2 | 0.5% full scale | ||
| OUTPUT SIGNALS | 54 | IO-Link v 1.1 (2 configurable outputs, PNP) | 56 | IO-Link v 1.1 (1 configurable output, PNP) | ||
| PROCESS CONNECTIONS |
2 | 1/4" NPT male | 10 | G 1/4 B male EN837 | 46 | G 1/4 A male ISO 1179-2 |
| 8 | 1/2" NPT male | 45 | 7/16-20 SAE J514 FIG 34B (Non-Adjustable) |
83 | G 1/2 B male EN837 | |
| ELECTRICAL CONNECTIONS |
25 | M12 x 1 (4-pin) | 25M | M12 x 1 (4-pin), heavy-duty | ||
| OPTIONS | ST8 | SS Threaded Orifice (0.8 mm) | ||||
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
| SPECIFICATIONS | |
| Pressure ranges | Compound and standard ranges from 1 bar through 1000 bar |
| Output parameters Number Function Switching Current Response time Zero Point Offset Damping Switch On Time Switching Voltage |
2 outputs, individually adjustable via IO-Link (PNP) Normally open, normally closed, window and hysteresis (adjustable via IO-Link) Max 250 mA ≤ 5 ms Max 3% of span (via IO-Link) 0 ms to 65 ms (via IO-Link) 1 s Power supply - 1 V |
| Accuracy parameters Accuracy, Switching output Long term drift Temperature error Temperature coefficients |
≤ 1.0% of span (optional ≤ 0.5% of span) ≤ 0.1 %, ≤ 0.2 % for ranges below 0.69 bar (10 psi) ≤ 1.5 % of span Mean TC zero point: ≤ 0.16 % of span/10K Mean TC span: ≤ 0.16 % of span/10K |
| Service life | 100,000,000 cycles (MTTF > 100 years) |
| Temperature ranges | Compensated -4 °F to 176 °F (-20 °C to 80 °C) Media -22 °F to 212 °F (-30 °C to 100 °C) w/metal conn. -40 °F to 257 °F (-40 °C to 125 °C) Ambient -22 °F to 212 °F (-30 °C to 100 °C) w/metal conn. -40 °F to 185 °F (-40 °C to 85 °C) Storage -40 °F to 158 °F ( -40°C to 70°C ) |
| Humidity | 45 - 75% r.h. |
| LED status | Green: Operation, Yellow: Warning, Red: Error |
| Current consumption | ≤ 25 mA, ≤ 0.3 A including switching current (one switching output), ≤ 0.6 A including switching current (two switching outputs) |
| Proof pressure | ≤ 600 bar (8000 psi) - 2 X, > 600 bar (8000 psi) - 1.5 X |
| Measuring element | <10 bar: 316L Stainless steel ≥10 bar: 316L, PH grade Stainless Steel |
| Housing material | 316L Stainless Steel |
| Connection | PBT GF30, 316L Stainless Steel |
| Environmental rating | IP65 and IP67 per IEC 60529 |
| Electromagnetic rating | RFI, EMI and ESD protection |
| Electrical protection | Protected against reverse polarity, over-voltage and short circuit |
| Shock | 100 g, 6 ms per IEC 60068-2-27, mechanical (metal connector: 1,000 g, 1 ms per IEC 60068-2-27, mechanical) |
| Vibration | 25 g, 10 to 2,000 Hz (according to IEC 60068-2-6, under resonance) |
| Weight | Approx. 2.8 oz |
*See user manual for detailed specifications

WARNING:This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
A: In many industrial applications, the terms pressure transmitter, pressure transducer and pressure sensor are used interchangeably. Traditionally, a transmitter referred to an instrument with a current output signal such as 4 mA to 20 mA, and a transducer referred to an instrument with a voltage output signal such as 0 Vdc to 10 Vdc. Today, all three terms are commonly used to describe electronic pressure measurement devices, so a NOSHOK pressure transmitter or transducer is often considered a type of pressure sensor.
A: When these terms originated there was a distinctive difference between the two. A transmitter was referred to as an instrument with a current signal, for example 4 mA to 20 mA, and a transducer was referred to as an instrument with a voltage signal, for example 0 Vdc to 10 Vdc. As time has progressed these terms are now commonly interchanged for reference to either output signal.
A: Proof pressure, which is higher than the full scale pressure point, is the limit that you can go to without affecting the performance and calibration of the transducer. The burst pressure, on the other hand, is the limit that you can go to before there is pressure chamber rupture and damage. An overload limit specification used sometimes means that proof and burst ratings are identical.
A: Radio Frequency Interference (RFI) and Electromagnetic Interference (EMI) refer to the effects electrical noise can have on instruments. RFI frequently comes from hand held walkie-talkies and EMI comes from AC motors in the vicinity of the instrument. ESD, or Electrostatic Discharge, comes from many sources including the application itself. CE compliant transmitters and transducers incorporate protection techniques and components to minimize most of the interference.
A: Most diaphragm seals can be used with pressure transducers and transmitters. The key is to assemble and fill the seal properly, being careful not to entrap air in the fill fluid.
A: The steam syphon is necessary in steam pressure applications. It is important to isolate the transmitter sensing diaphragm from the high temperature encountered with steam pressure applications.
A: As with other pressure measurement instruments including gauges, pressure pulsations and spikes are issues with pressure transmitters. Whenever the pressure of an incompressible fluid is measured, there is the potential for pulsations and spikes, which can damage pressure transmitters. An orifice installed in the pressure connection by NOSHOK can protect the transmitter from damage. Where there is the possibility of clogging the small orifice, an attachable piston snubber is recommended.
A: All pressure measurements are inherently differential in theory. Gauge pressure is referenced to ambient atmospheric pressure, and absolute pressure is referenced to a vacuum contained in an evacuated chamber within the transmitter. The level measurement is also a differential measurement, with its reference to ambient atmospheric pressure. In order for the submersible level measurement to be referenced to atmospheric, the cable contains a vent tube which runs the complete length of the cable and vents to atmospheric pressure at the junction box connection, which is out of the liquid.
A: The transmitter measures the hydrostatic pressure produced by the liquid level higher than the point where the instrument is located. The higher the liquid, the higher the pressure.
A: Voltage output transducers are available with a fourth connection which is electrically the same as the power supply common to connect to wiring configurations that require it.
A: A smaller diaphragm is less easily damaged, and positioning the sensors directly behind the diaphragm minimizes fill fluid and enables active temperature compensation directly at the point of measurement.
A: A turndown ratio, also commonly known as rangeability, refers to the ratio between the full-scale range and the minimum point of measure, indicating the range in which an instrument can accurately measure the media. For example, if a pressure transmitter has a maximum calibration range of 0 to 300 psi and a turndown ratio of 10:1, the span can be adjusted anywhere between 0 to 30 psi and 0 to 300 psi. The higher the turndown ratio, the higher the rangeability, which can also help minimize required inventory.