Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SERIES | 1950 | |||||
INPUT SIGNALS | C | Current | V | Voltage | R | Resistance |
DISPLAYS | 1 | Reflective | 2 | Backlight | ||
OPTION CARDS | 0 | None | 2 | Dual sinking open collector | 7 | RS485 comm |
1 | Single relay | 6 | RS232 comm | |||
OPTIONAL ENCLOSURES | ENC1 | Black painted steel | ENC2 | Off-White fiberglass |
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SPECIFICATIONS | |
Input signals | 4 mA to 20 mA, 0 Vdc to 10 Vdc (optional RTD and Thermocouple) |
Process display | 5 digit, 0.48" liquid crystal display |
Key pad | 2 programmable function keys |
Power requirement | 9 Vdc to 28 Vdc Power consumption 10 mA typical, 95 mA with max. display intensity |
Electrical connection | Screw terminals at back of case |
Memory | EEPROM |
Accuracy | <0.1% of full scale |
Humidity | 85% max., non-condensing |
Vibration | 5-500 Hz, 5g |
Shock | 30 g |
Normal rejection mode | 60 dB 50/60 Hz |
Altitude | Up to 2,000 meters |
Update rate | 500 msec |
Temperature ranges | Operating 31 °F to 167 °F (-35 °C to 75 °C) Effect ≤ 0.1% of full scale /18 °F (10 °C) Storage -31 °F to 185 °F (-35 °C to 85 °C) |
Electromagnetic rating | CE compliant to EMC norm EN 61326-1 RFI, EMI and ESD protection |
Environmental rating | NEMA 4, 4X, IP65 (front of display only) |
Filtering | 0.25 seconds to 1 second, selectable |
Min/Max reading | Captures and stores min/max measurement |
User inputs | 1 programmable, 28 Vdc max. continuous |
Linearization | 2 point |
Weight | 3 oz. |
Option cards | Serial communication (RS232 or RS485) Analog output (0-20 mA, 4-20 mA or 0-10 Vdc) Single or Dual Relay (NPN or PNP type) USB programming |