Use the PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to the new PT Series transmitters.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SERIES | PTI20 | |||||
ADJUSTABLE PRESSURE RANGES |
5psig | Min. span 1.45 psi, max. span 5.8 psi (lowest vacuum pressure -5.8 psig) |
55psig | Min. span 14.5 psi, max. span 58 psi (lowest vacuum pressure -15 psig) |
350psig | Min. span 87 psi, max. span 350 psi (lowest vacuum pressure -15 psig) |
20psig | Min. span 5.8 psi, max. span 23 psi (lowest vacuum pressure -15 psig) |
145psig | Min. span 29 psi, max. span 145 psi (lowest vacuum pressure -15 psig) |
1150psig | Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) |
|
psig = gauge pressure All ranges can be user scaled in vacuum or compound. | ||||||
ACCURACY | 1 | ±0.2% of adjusted span (4:1 turndown) | ||||
OUTPUT SIGNALS | 1 | 4 mA to 20 mA, 2-wire | 43 | 4 mA to 20 mA, 2-wire with HART® | ||
PROCESS CONNECTIONS |
8 | 1/2" NPT male | 75 | Threaded flush diaphragm for flange (flange not included) |
79 | 1" PMC connection |
69 | 1/2" NPT female | 76 | 1-1/2" ANSI 150# Flange | 80 | 1-1/2" PMC connection | |
73 | 1" NPT male flush | 77 | 2" ANSI 150# Flange | |||
74 | 1-1/2" NPT male flush | 78 | 3" ANSI 150# Flange | |||
ELECTRICAL CONNECTIONS |
25 | M12 x 1 (4-pin) | 28 | 1/2” NPT Female | 71 | PG9 Cable Gland |
OPTIONS | CC | Certified Calibration | RMT-10 | Remote Mount Head with 10 ft cable * | TC | Transparent Cover (for display) |
*Custom lengths available, consult factory. Includes mounting bracket.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SPECIFICATIONS | |
Output signals | 4 mA to 20 mA 2-wire, 4 mA to 20 mA 2-wire with HART® |
Adjustable pressure ranges | 5 psig to 1,160 psig (All ranges are user adjustable from vacuum to full scale) |
Accuracy | ±0.2% of adjusted span (Turn down 4:1) |
Stability | <0.1%/year |
Adjustment | By 3 push buttons on display or optional HART® protocol |
Response time | <100 ms |
Service life | >10 years |
Temperature ranges | Media -4 °F to 176 °F (-20 °C to 80 °C) Ambient -4 °F to 158 °F (-20 °C to 70 °C) Flange -4 °F to 212 °F (-20 °C to 100 °C) |
Power requirement* | 12 Vdc to 36 Vdc |
Measuring element | 316 Stainless Steel (Hastelloy C or Tantalum optional) |
Connection | 316 Stainless Steel |
Housing material | 304 Stainless Steel (316 Stainless Steel optional) |
Environmental rating | IP66 (IP68 optional) |
Electromagnetic rating | Built to suppress RFI, EMI and ESD protection |
Weight | Approximately 3.30 lb. (Depending on process connection) |
*Unregulated
UNINSTALLED OPTIONS & ACCESSORIES | |
PTI-FLANGE-15-150LB | 1-1/2" ANSI 150# Flange only |
PTI-FLANGE-20-150LB | 2" ANSI 150# Flange only |
PTI-FLANGE-30-150LB | 3" ANSI 150# Flange only |
PTI-10-PMC-WA | 1" PMC Weld Adapter |
PTI-15-PMC-WA | 1-1/2" PMC Weld Adapter |
PTI-PMC-GASKET-15 | PTFE Gasket for 1-1/2" PMC |
PTI-PMC-ORING-1 | FKM O-Rings for 1" PMC |
PTI-FLANGE-GASKET | PTFE Gasket for Flush diaphragm to Flange |
WARNING:This product can expose you to chemicals including Lead and Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov