Use the PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to the new PT Series transmitters.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
| SERIES | PTI20 | |||||
| ADJUSTABLE PRESSURE RANGES |
5psig | Min. span 1.45 psi, max. span 5.8 psi (lowest vacuum pressure -5.8 psig) |
55psig | Min. span 14.5 psi, max. span 58 psi (lowest vacuum pressure -15 psig) |
350psig | Min. span 87 psi, max. span 350 psi (lowest vacuum pressure -15 psig) |
| 20psig | Min. span 5.8 psi, max. span 23 psi (lowest vacuum pressure -15 psig) |
145psig | Min. span 29 psi, max. span 145 psi (lowest vacuum pressure -15 psig) |
1150psig | Min. span 290 psi, max. span 1,160 psi (lowest vacuum pressure -15 psig) |
|
| psig = gauge pressure All ranges can be user scaled in vacuum or compound. | ||||||
| ACCURACY | 1 | ±0.2% of adjusted span (4:1 turndown) | ||||
| OUTPUT SIGNALS | 1 | 4 mA to 20 mA, 2-wire | 43 | 4 mA to 20 mA, 2-wire with HART® | ||
| PROCESS CONNECTIONS |
8 | 1/2" NPT male | 75 | Threaded flush diaphragm for flange (flange not included) |
79 | 1" PMC connection |
| 69 | 1/2" NPT female | 76 | 1-1/2" ANSI 150# Flange | 80 | 1-1/2" PMC connection | |
| 73 | 1" NPT male flush | 77 | 2" ANSI 150# Flange | |||
| 74 | 1-1/2" NPT male flush | 78 | 3" ANSI 150# Flange | |||
| ELECTRICAL CONNECTIONS |
25 | M12 x 1 (4-pin) | 28 | 1/2” NPT Female | 71 | PG9 Cable Gland |
| OPTIONS | CC | Certified Calibration | RMT-10 | Remote Mount Head with 10 ft cable * | TC | Transparent Cover (for display) |
*Custom lengths available, consult factory. Includes mounting bracket.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
| SPECIFICATIONS | |
| Output signals | 4 mA to 20 mA 2-wire, 4 mA to 20 mA 2-wire with HART® |
| Adjustable pressure ranges | 5 psig to 1,160 psig (All ranges are user adjustable from vacuum to full scale) |
| Accuracy | ±0.2% of adjusted span (Turn down 4:1) |
| Stability | <0.1%/year |
| Adjustment | By 3 push buttons on display or optional HART® protocol |
| Response time | <100 ms |
| Service life | >10 years |
| Temperature ranges | Media -4 °F to 176 °F (-20 °C to 80 °C) Ambient -4 °F to 158 °F (-20 °C to 70 °C) Flange -4 °F to 212 °F (-20 °C to 100 °C) |
| Power requirement* | 12 Vdc to 36 Vdc |
| Measuring element | 316 Stainless Steel (Hastelloy C or Tantalum optional) |
| Connection | 316 Stainless Steel |
| Housing material | 304 Stainless Steel (316 Stainless Steel optional) |
| Environmental rating | IP66 (IP68 optional) |
| Electromagnetic rating | Built to suppress RFI, EMI and ESD protection |
| Weight | Approximately 3.30 lb. (Depending on process connection) |
*Unregulated
| UNINSTALLED OPTIONS & ACCESSORIES | |
| PTI-FLANGE-15-150LB | 1-1/2" ANSI 150# Flange only |
| PTI-FLANGE-20-150LB | 2" ANSI 150# Flange only |
| PTI-FLANGE-30-150LB | 3" ANSI 150# Flange only |
| PTI-10-PMC-WA | 1" PMC Weld Adapter |
| PTI-15-PMC-WA | 1-1/2" PMC Weld Adapter |
| PTI-PMC-GASKET-15 | PTFE Gasket for 1-1/2" PMC |
| PTI-PMC-ORING-1 | FKM O-Rings for 1" PMC |
| PTI-FLANGE-GASKET | PTFE Gasket for Flush diaphragm to Flange |

WARNING:This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov