Use the PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to the new PT Series transmitters.
Note: Thermowells are recommended for pressure, corrosive fluids and high velocity applications.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
DIAL SIZE | 10 | 1" ** | 18 | 1-3/4" | 20 | 2" |
CASE TYPE | 150 | Back connection | ||||
STEM LENGTHS | 050 | 5" | 120 | 12" † | ||
080 | 8" | 180 | 18" † | |||
TEMPERATURE RANGES Dual Scale °F/ °C (Not available on 1" model) |
-100/100 F/C | -100 °F/°C to 100 °F/°C | 0/250 F/C | 0° °F/°C to 250 °F/°C | 50/500 F/C | 50° to 500 °F/°C |
-40/160 F/C | -40 °F/°C to 160 °F/°C | 20/240 F/C | 20 °F/°C to 240 °F/°C | 150/750 F/C | 150 °F/°C to 750 °F/°C | |
0/140 F/C | 0 °F/°C to 140 °F/°C | 25/125 F/C | 25°F/°C to 125 °F/°C | 200/1000 F/C | 20°F/°C to 1,000 °F/°C* | |
0/180 F/C | 0 °F/°C to 180 °F/°C | 50/300 F/C | 50 °F/°C to 300 °F/°C | |||
0/220 F/C | 0 °F/°C to 220 °F/°C | 50/400 F/C | 50 °F/°C to 400 °F/°C | |||
Single Scale °F | -100/100 F | -100 °F to 100 °F | 0/220 F | 0° to 220 °F** | 50/400 F | 50° to 400 °F |
-50/120 F | -50 °F to 120 °F | 0/250 F | 0 °F to 250 °F | 50/500 F | 50 °F to 500 °F** | |
-40/160 F | -40 °F to 160 °F** | 20/240 F | 20 °F to 240 °F | 50/550 F | 50 °F to 550 °F | |
0/140 F | 0 °F to 140 °F | 25/125 F | 25 °F to 125 °F** | 150/750 F | 150 °F to 750 °F** | |
0/180 F | 0 °F to 180 °F | 50/250 F | 50 °F to 250 °F | 200/1000 F | 200 °F to 1,000 °F* | |
0/200 F | 0 °F to 200 °F | 50/300 F | 50 °F to 300 °F | |||
Single Scale °C | -75/175 C | -75 °C to 175 °C | -10/110 C | -10 °C to 110 °C** | 0/300 C | 0 °C to 300 °C |
-50/100 C | -50 °C to 100 °C | 0/50 C | 0 °C to 50 °C** | 0/400 C | 0 °C to 400 °C | |
-50/25 C | -50 °C to 25 °C | 0/100 C | 0 °C to 100 °C | 100/400 C | 100 °C to 400 °C | |
-50/50 C | -50 °C to 50 °C | 0/150 C | 0 °C to 150 °C | 100/550 C | 100 °C to 550 °C* | |
-40/70 C | -40 °C to 70 °C** | 0/200 C | 0 °C to 200 °C | |||
-20/120 C | -20 °C to 120 °C | 0/250 C | 0 °C to 250 °C** | |||
Consult factory for additional temperature ranges | ||||||
OPTIONS | LL | Polycarbonate Lens | PS | Pocket Sheath*** | ST | Stainless Steel Tagging |
PL | Acrylic Lens† | SL | Silicone Filled † | TG | Tempered Glass Lens†† |
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
MODELS | SPECIFICATIONS | |
---|---|---|
Case & Bezel | All 150 Series | 304 Stainless Steel |
Lens | All 150 Series | Instrument glass |
Pointer | All 150 Series | Aluminum, black finished |
Stem diameter | All 150 Series | 0.150" (3.81 mm) |
Accuracy | All 150 Series | ±1% full scale, Grade A, ASME B40.3 |
Dial | All 150 Series | Anodized Aluminum with large black numbers and graduations |
Wetted parts | All 150 Series | 304 Stainless Steel |
Hermetic seal | All 150 Series | Per ASME B40.3 dustproof and leakproof |
Bimetal coil | All 150 Series | Silicone coated helix coil on ranges below 500 °F for vibration dampening, maximum heat transfer and response time |
Over temperature limits | All 150 Series | Up to 250 °F 100%; 250 °F to 550 °F 50%; 550 °F to 1,000 °F continuous use up to 800 °F; intermitent use over 800 °F |
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.
WARNING:This product can expose you to chemicals including Lead and Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov