Use the PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to the new PT Series transmitters.
Note: Thermowells are recommended for pressure, corrosive fluids and high velocity applications.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
DIAL SIZES | 10 | 1" ** | 18 | 1-3/4" | 30 | 3" |
14 | 1-3/8" ** | 20 | 2" | |||
CASE TYPES | 350 | Back connection | ||||
STEM LENGTHS | 050 | 5" ** | 120 | 12" | ||
080 | 8" ** | 180 | 18" | |||
TEMPERATURE RANGES Dual Scale °F/°C (Not available on 1" model) |
-100/100 F/C | -100 °F/C to 100 °F/C | 0/250 F/C | 0 °F/C to 250 °F/C | 50/500 F/C | 50 °F/C to 500 °F/C |
-40/160 F/C | -40 °F/C to 160 °F/C | 20/240 F/C | 20 °F/C to 240 °F/C | 150/750 F/C | 150 °F/C to 750 °F/C | |
0/140 F/C | 0 °F/C to 140 °F/C | 25/125 F/C | 25 °F/C to 125 °F/C† | 200/1000 F/C | 200 °F/C to 1,000 °F/C* | |
0/180 F/C | 0 °F/C to 180 °F/C | 50/300 F/C | 50 °F/C to 300 °F/C | |||
0/220 F/C | 0 °F/C to 220 °F/C | 50/400 F/C | 50 °F/C to 400 °F/C | |||
Single Scale °F | -100/100 F | -100 °F to 100 °F | 0/250 F | 0 °F to 250 °F | 50/550 F | 50 °F to 550 °F |
-50/120 F | -50 °F to 120 °F | 20/240 F | 20 °F to 240 °F | 100/800 F | 100 °F to 800 °F** | |
-40/160 F | -40 °F to 160 °F** | 25/125 F | 25 °F to 125 °F** | 150/750 F | 150 °F to 750 °F** | |
0/140 F | 0 °F to 140 °F | 50/250 F | 50 °F to 250 °F | 200/1000 F | 200 °F to 1,000 °F* | |
0/180 F | 0 °F to 180 °F | 50/300 F | 50 °F to 300 °F | |||
0/200 F | 0 °F to 200 °F | 50/400 F | 50 °F to 400 °F | |||
0/220 F | 0 °F to 220 °F** | 50/500 F | 50 °F to 500 °F** | |||
Single Scale °C | -75/175 C | -75 °C to 175 °C | -10/110 C | -10 °C to 110 °C** | 0/300 C | 0 °C to 300 °C |
-50/100 C | -50 °C to 100 °C | 0/50 C | 0 °C to 50 °C** | 0/400 C | 0 °C to 400 °C | |
-50/25 C | -50 °C to 25 °C | 0/100 C | 0 °C to 100 °C | 100/400 C | 100 °C to 400 °C | |
-50/50 C | -50 °C to 50 °C | 0/150 C | 0 °C to 150 °C | 100/550 C | 100 °C to 550 °C* | |
-40/70 C | -40 °C to 70 °C** | 0/200 C | 0 °C to 200 °C | |||
-20/120 C | -20 °C to 120 °C | 0/250 C | 0 °C to 250 °C** | |||
Consult factory for additional temperature ranges | ||||||
OPTIONS | LL | Polycarbonate Lens | PS | Pocket Sheath*** | TG | Tempered Glass Lens† |
PL | Acrylic Lens | ST | Stainless Steel Tagging |
Note: All 316 Stainless Steel construction (case, bezel, wetted parts) is available. Please consult factory.
* Thermometers with temperature ranges 200/1000 °F and 100/500 °C are not recommended for continuous use above
800 °F/425 °C. For intermittent use only.
** 10-350 and 14-350 models are only available in these stem lengths and ranges.
*** Available for 5" or 8" stem lengths only.
† Not available on 10-350 model. Also not available with Silicone Filles (SL) option.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
MODELS | SPECIFICATIONS | |
Case & Bezel | All 350 Series | 304 Stainless Steel; 316 Stainless Steel optional |
Lens | 14-350 All other 350 Series models |
Convex Polycarbonate Instrument glass |
Pointer | All 350 Series | Aluminum, black finished |
Stem diameter | All 350 Series | 0.150" (3.81 mm) |
Accuracy | All 350 Series | ±1% full scale, Grade A, ASME B40.3 |
Dial | All 350 Series | Anodized Aluminum with large black numbers and graduations |
Wetted parts | All 350 Series | 304 Stainless Steel; 316 Stainless Steel optional |
Hermetic seal | All 350 Series | Per ASME B40.3 dustproof and leakproof |
Bimetal coil | All 350 Series | Silicone coated helix coil on ranges below 500 °F for vibration dampening, maximum heat transfer and response time |
Over temperature limits | All 350 Series | Up to 250 °F 100%; 250 °F to 550 °F 50%; 550 °F to 1,000 °F continuous use up to 800 °F; intermittent use over 800 °F |
Recalibrator | All 350 Series | External reset |
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.
WARNING:This product can expose you to chemicals including Lead and Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov