800 Series Platinum Resistance Temperature Transmitters

REQUEST A QUOTE VIEW BY PART NUMBER
Download Literature
Oil & Gas

Municipal & Industrial Water Wastewater Processing Solutions - Transmitters, Gauges, Diaphragm Seals

  • Proven 100 Ω platinum resistance sensor provides reliability, stability & unbeatable performance
  • Economical price
  • Standard temperature ranges from -40 °F to 120 °F through 50 °F to 400 °F
  • Wide variety of temperature ranges and connections
  • Quick response time
  • 316 Stainless Steel housing
  • Burnout protection from 3.3 mA to 23 mA
  • Also available with our 1800 Series attachable loop indicator (see options & accessories below)
  • Built to suppress RFI, EMI, and ESD

     Note: Thermowells are recommended for pressure, corrosive fluids and high velocity applications.

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SERIES 800              
TEMPERATURE RANGES -40/120 -40 °F to 120 °F 0/200 0 °F to 200 °F 25/125 25°F to 125 °F    
0/100 0°F to 100 °F 0/250 00 °F to 250 °F 50/300 50 °F to 300 °F    
0/140 0°F to 140 °F 20/240 20 °F to 240 °F 50/400 50 °F to 400 °F    
ACCURACY 1 Class B + (±0.5 % BFSL)            
OUTPUT SIGNALS 1 4 mA to 20 mA, 2-wire 3 1 Vdc to 5 Vdc, 3-wire    
2 0 Vdc to 5 Vdc, 3-wire 5 0 Vdc to 10 Vdc, 3-wire        
PROCESS CONNECTIONS 2 1/4" NPT male     48 1/2" NPT male w/adjustable compression fitting
8 1/2" NPT male            
ELECTRICAL CONNECTIONS 1 DIN EN 175301-803 Form A with 36" cable 14 DIN EN 175301-803 Form A with ISO 4400 
1/2″ NPT female conduit 
8 DIN EN 175301-803 Form A  25 M12 x 1(4pin)    
STEM LENGTHS 025 2.5" 060 6" 120 12"    
040 4" 090 9"        
STEM DIAMETERS 6 6 mm 8 8 mm        

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SPECIFICATIONS
Output signals 4mA to 20 mA 2-wire, 0 Vdc to 5 Vdc 3-wire
0 Vdc to 10 Vdc 3-wire, 1 Vdc to 5 Vdc 3-wire
Temperature ranges Standard ranges from -40 °F to 400 °F
Accuracy:
    Measuring element
    Output
 
Class B per EN 60751 (IEC 751)
±[0.30 + 0.005*ltl] °C
±0.5% full scale
Sensor protection Burnout protected from 3.3 mA to 23 mA
Power supply* 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire)
10 Vdc to 30 Vdc (0 Vdc to 5 Vdc, 3-wire)
10 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire)
Load limitations ≤ (VPower - 10)/0.020 Amp for 4 mA to 20 mA output
≤ 5,000 Ω for 1 Vdc to 5 Vdc output
≤ 10,000 Ω for 0 Vdc to 10 Vdc output
≤ 4,500 Ω for 0.5 Vdc to 4.5 Vdc output
Wetted materials 316 Stainless Steel
Housing materials 316 Stainless Steel
Max. operating pressure 6 mm: 725 psi
8 mm: 1,500 psi
Ambient temperature -40 °F to 185 °F (-40 °C to 85 °C)
Storage temperature -40 °F to 185 °F (-40 °C to 85 °C)
Environmental rating IP65 according to EN 60529/IEC 529
Electromagnetic rating Built to suppress RFI, EMI and ESD protection
Electrical protection Reverse polarity, over-voltage and short circuit protection
Weight Approximately 4 oz.

Options & Accessories

NOSHOK 1800 Series Attachable Loop-Powered Digital Indicators can be fitted to certain NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the Hirschmann (DIN 43650A) connector.

View NOSHOK 1800 Series Attachable Loop-Powered Digital Indicators

Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.

View NOSHOK Thermowells

WARNING:This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Temperature

Frequently Asked Questions

A: Maximum temperature for a bi-metal thermometer in continuous use is 800 ∞F but it can be used in applications intermittently up to 1000 ∞F.

A: RTDs, or resistance temperature devices, are temperature sensors that are commonly used in a variety of industrial applications including industrial boilers, petrochemical, exhaust gas monitoring and food processing. RTD sensors have a higher accuracy than thermocouples and thermistors over a wide temperature range, and are more stable over time. Simply put, an RTD is a sensor whose resistance changes with temperature in a consistent repeatable manner.

A: An RTD can provide highly accurate and consistent temperature measurements because the change in resistance of certain materials is so predictable. Most RTD sensors have a response time between 0.5 to 5 seconds and commonly feature a platinum-based element, but can also be constructed with nickel or copper. RTDs made with platinum, also known as PRTs or platinum resistance thermometers, are used most often today due to their higher temperature capabilities, better stability and repeatability. Probe type RTDs generally consist of a rigid probe with direct mounted connector or extension cable. Assembly type models usually incorporate a rigid probe assembled with a connection head or junction box. Direct immersion probes have the RTD protective sheath, the probe, welded to a process fitting similar to temperature gauges, which offers better response but limited mechanical protection and limited access to a process under operation. Assemblies for thermowells have the RTD probe typically spring loaded in the connection fitting, which ensures good thermal contact and removes dead space in the well tip.

A: An RTD connection head provides a clean, protected area for mounting a terminal block or transmitter, and can be rated for indoor or outdoor use, providing protection against dust, rain, splashing and water from washdown hoses. NOSHOK RTD connection heads are available in cast aluminum, white polypropylene and cast 316 stainless steel. White polypropylene is popular for sanitary and chemical applications, while stainless steel is often used in food, pharmaceutical, biotech and chemical applications. Aluminum and stainless steel are preferred for industrial applications. Intrinsically safe explosion-proof enclosures are also available for hazardous environments.

A: The physical principles of vapor actuation require that the dial face be printed with a nonlinear, progressively graduated temperature scale. These instruments are available for direct mounting, or for remote mounting with capillary lengths up to 100 feet. Sensing bulb length is dependent upon the capillary length selected; a longer capillary length will require a longer sensing bulb length.

A: A thermowell would offer additional protection and is the preferred method if the application allows for one to be installed.

A: The sliding compression fitting can be used to adjust the immersion depth of the instrument's stem. The adjustable union connection can be used to reposition the dial face for better viewing.

A: A thermowell is used with a temperature-sensing instrument to provide a protective barrier between the instrument and the process media. Thermowells can provide protection from harmful process influences including flow, high pressure and harsh environments, reducing the possibility of damage to the temperature instrument and providing protection to the operator. Thermowells also allow easier service to the instrument and reduce operating costs by allowing the temperature instrument to be removed and replaced without shutting down and draining the process.

A: The most commonly used types of thermowells are threaded, socket weld, weld-in and flanged connections. A threaded thermowell is screwed directly into the process through the tapped pipe wall or via a thermowell threadolet. Socket weld thermowells can be welded directly into the socket of the weldolet or into the wall of the pipe. Weld-in thermowells are welded directly into the piping or a process vessel. Flanged thermowells incorporate a flange collar located on the mating flange, which is paired with a pipe nozzle.

A: A lagging extension, often referred to as the thermowell's T length, is located on the cold side of the process connection and is usually an extension of the hex length of the thermowell. The lagging extension enables the probe and thermowell to extend through insulation or walls.

A: The bore depth S of a thermowell can be used as a reference for the maximum stem length. The S must equal or exceed the length of the sensitive portion of the instrument's stem.

More questions? Contact NOSHOK Customer Support at info@noshok.com