Use the PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to the new PT Series transmitters.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SERIES | 810 | |||||||
TEMPERATURE RANGES | -22/125 | -22 °F to 125 °F | -22/302 | -22 °F to 302 °F | 0/200 | 0 °F to 200 °F | ||
-22/250 | -22 °F to 250 °F | 0/100 | 0 °F to 100 °F | 0/300 | 0 °F to 300 °F | |||
(L/H) Custom ranges available on request, specify low and high ranges (70 °F minimum span) | ||||||||
ACCURACY | 1 | PT1000 Class A ±0.8 °F (±0.45 °C) | ||||||
OUTPUT SIGNAL | 1 | 4 mA to 20 mA, 2-wire | ||||||
PROCESS CONNECTIONS | 2 | 1/4" NPT male | 8 | 1/2" NPT Male | ||||
ELECTRICAL CONNECTION | 25 | M12 x 1 (4-pin) | ||||||
STEM LENGTHS | 010 | 1" | 030 | 3" | 080 | 8" | ||
020 | 2" | 040 | 4" | 120 | 12" | |||
025 | 2.5" | 060 | 6" | 140 | 14" | |||
STEM DIAMETERS | 6 | 6 mm |
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SPECIFICATIONS | |
Output signal | 4mA to 20 mA, 2-wire |
Temperature ranges | Standard ranges from -22 °F to 302 °F (-30 °C to 150 °C) |
Accuracy: Measuring element Temperature sensor Accurary 1,2 |
PT1000 Class A For °F: ±[1.8*(0.15 + 0.002 (t - 32) / 1.8)] For °C: ±(0.15 K + 0.002 I t I) per EN 60751 ± 0.80 °F (+- 0.45 °C) |
Failure signal: Sensor burnout Sensor short circuit |
≥ 21.0 mA ≤ 3.6 mA |
Power requirement* | 10 Vdc to 30 Vdc |
Environmental temperature affect | 0.1% of span / 18 °F (10 °C) |
Load limitations | ≤ (Supply Voltage - 10 Volts)/0.023 A |
Wetted materials | 316 Stainless Steel |
Housing materials | 316 Stainless Steel |
Ambient temperature | -40 °F to 185 °F (-40 °C to 85 °C) |
Storage temperature | -40 °F to 185 °F (-40 °C to 85 °C) |
Electromagnetic rating | CE compliant to EMC norm EN 61326 RFI, EMI and ESD protection |
Electrical protection | Reverse polarity, over-voltage and short circuit protection |
Max. operating pressure | 3,915 psi (270 bar)3 |
Environmental protection | IP67 |
* Unregulated
1 Maximum uncertainty calculated @ maximum span, maximum measurement temperature, and ambient temperature
2 Maximum uncertainty includes Usensing element, Usensor measurement, Uoutput linearization
3 Pressure rating may vary based on the process medium, temperature and flow rate
Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.
WARNING:This product can expose you to chemicals including Lead and Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov