Use the PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to the new PT Series transmitters.
Note: Thermowells are recommended for pressure, corrosive fluids and high velocity applications.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SERIES | 822 | Bottom connection | 823 | Back connection | ||||
ACCURACY | 1 | ≤0.22% full scale | 2 | ≤0.1% full scale | ||||
PROCESS CONNECTIONS | 0 | None | 8 | 1/2" NPT Male | ||||
2 | 1/4" NPT Male | 48 | 1/2" NPT Male w/sliding compression fitting * | |||||
TEMPERATURE RANGES | -58/392 | -58° to 392 °F | -50/200C | -50° to 200 °F | ||||
STEM LENGTHS ** | 025 | 2.5" | 060 | 6" | 120 | 12" | 180 | 18" |
040 | 4" | 090 | 9" | 150 | 15" | 240 | 24" | |
STEM DIAMETERS | 2 | 1/4" | 4 | 1/2" | 8 | 8 mm | ||
3 | 3/8" | 6 | 6 mm |
* Add 2" to stem length for this option.
** Consult factory for additional stemp length options.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SPECIFICATIONS | |
Temperature ranges | Standard ranges from -58 °F to 392 °F (-50 °C to 200 °C) |
Temperature sensor | RTD (PT100 DIN EN 60751, Class A) |
Housing material | 316 Stainless Steel |
Probe material | 316 Stainless Steel standard |
Maximum pressure | 500 psig (on probe) |
Power requirement | Lithium battery (3.6 V) |
Supply effect | 0.005%/V |
Accuracy | ≤0.22% full scale; ≤0.1% full scale optional |
Display | 4-digit LCD |
Display resolution | ±0.02% F.S. ±1 digit |
RFI effect | 1% or less typical |
Temperature ranges | Ambient -40 °F to 176 °F (-40 °C to 80 °C) Effect <0.01% FS/ °C Storage -58 °F to 185 °F (-50 °C to 85 °C) |
Environmental protection | NEMA 4/ IP 65 |
Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.
WARNING:This product can expose you to chemicals including Lead and Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov