Use the PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to the new PT Series transmitters.
Note: Thermowells are recommended for pressure, corrosive fluids and high velocity applications.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SERIES | 900 | |||||
TEMPERATURE RANGES | -50/400 | -50 °F to 400 °F | -330/1100 | -330 °F to 1,100 °F | ||
-50/750 | -50 °F to 750 °F | |||||
ACCURACIES | 1 | ±0.12% (±0.3 °C) at 0 °C, Class B | 3 | ±0.04% (±0.1 °C) at 0 °C, Class AA | ||
2 | ±0.06% (±0.15 °C) at 0 °C, Class A | |||||
ELEMENT TYPES | C | PT100 Ω at 0 °C | M | PT1000 Ω at 0 °C | ||
CIRCUIT TYPES | 1 | Single, 2-wire | 3 | Single, 4-wire | 5 | Dual, 3-wire |
2 | Single, 3-wire | 4 | Dual, 2-wire | 6 | Dual, 4-wire | |
PROCESS CONNECTIONS | 0 | None | 8 | 1/2" NPT Male | ||
1 | 1/8" NPT Male | 48 | 1/2" NPT Male w/sliding compression fitting ** | |||
2 | 1/4" NPT Male | 61 | Spring loaded 1/2" NPT **, *** | |||
ELECTRICAL CONNECTIONS | 6 | 1/2" NPT conduit with 36" cable | 48 | M12 x 1 (5-pin) * | ||
36 | Integral cable 36" | 49 | 3-pin RTD plug | |||
37 | 1/2" NPT conduit with 6" flying leads | 50 | M12 x 1 (8-pin) | |||
STEM LENGTHS | 025 | 2.5" | 090 | 9" | 180 | 18" |
040 | 4" | 120 | 12" | 240 | 24" | |
060 | 6" | 150 | 15" | |||
STEM DIAMETERS | 1 | 1/8" | 3 | 3/8" | 6 | 6 mm |
2 | 1/4" | 4 | 1/2" |
* Single circuit types only
** Add 2" to stem length for this option. If installing with thermowells, Process Connection option 48 or 61 must be selected
*** Only available with Electrical Connection options 6 and 37
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SPECIFICATIONS | |
Temperature ranges | -50 °F to 400 °F (-50 °C to 200 °C) -50 °F to 750 °F (-50 °C to 400 °C) -330 °F to 1,100 °F (-200 °C to 600 °C) |
Sheath material | 316 Stainless Steel |
Finish (standard) | 32 micro-inches maximum |
Pressure rating | 500 psi (34.5 bar), tube only |
RTD element | PT100 Ω @ 32 °F (0 °C), α=0.00385 IEC 751 |
Lead wires | Stranded 22 AWG standard, PVC or PTFE insulation |
Self-heating | 50 mW / °C typical in moving water |
Insulation resistance | Single element probes: 100 mega Ω/min. at 500 Vdc, leads to case Dual element probes: 100 mega Ω/min. at 100 Vdc, between element and leads to case |
Transition | Sheath to wire transition max. temperature 266 °F (130 °C) |
Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument.
WARNING:This product can expose you to chemicals including Lead and Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov