Use the PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to the new PT Series transmitters.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SERIES | SZ | Connector | ||
MATERIALS | C | Steel | S | Stainless steel |
CONNECTOR TYPES | 1 | Short stabilized pair* | 4 | Long stabilized pair with flange adaptor** |
2 | Short stabilized pair with flange adaptor** | 5 | Non-stabilized pair | |
3 | Long stabilized pair* | |||
OPTIONS† | DK1 | One Piece Dielectric Gasket, Pair | DK2 | PTFE Gasket with Dielectric Shim, Pair |
DK1-SS | One Piece Dielectric Gasket, Pair w/SS Bolts | DK2-SS | PTFE Gasket with Dielectric Shim, Pair w/SS Bolt |
† More information on Dielectric Kits
* For flat installations (orifice fitting)
** For round installations (orifice flange)
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SPECIFICATIONS | |
Materials | Zinc-nickel plated Carbon Steel, 316 Stainless Steel |
Bolts | Carbon Steel |
Connection | 1/2" NPT-flange |
Pressure rating | 10,000 psi at 200 °F |
Orifice | 0.375" |
Weight | Approximately 3.3 lb. (Short stabilized) Approximately 4.5 lb. (Longs stabilized) Approximately 2.9 lb. (Non-stabilized) |
Dielectric Kits are designed to maintain the integrity and reliability of the pipeline and piping system through safety and corrosion protection. Dielectric Kits provide a non-conductive barrier between the process piping and the instrument and isolate components from the effects of electrical current. By eliminating metal-to-metal contact, current is halted to prevent corrosion and aid in the cathodic protection of the system.
DK1
DK2
Specifications:
All 316SS products meet the requirements of NACE MR0175/ISO 15156-3.
WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
The NOSHOK Direct Connect Assembly provides an installation that keeps the meter close to the orifice taps for accurate flow measurements.
View the NOSHOK Direct Connect Assembly
WARNING:This product can expose you to chemicals including Lead and Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov