Non-Replaceable

Home » Products » Diaphragm Seals » Non-Replaceable » Type 5 All Non-Metallic, Non-Replaceable Diaphragm Seals

Type 5 All Non-Metallic, Non-Replaceable Diaphragm Seals

REQUEST A QUOTE VIEW BY PART NUMBER
Download Literature
Water/
Wastewater
  • For wastewater and chemical feed applications, as well as most applications with a corrosive media
  • Constructed of corrosion-resistant PP glass fiber reinforced upper housing and PP, PVC or PVDF lower housing
  • Protects pressure or vacuum instruments used on ultra-pure or highly corrosive fluid lines such as demineralized water, sulfuric acid, hydrochloric acid, and caustics
  • PTFE coated EPDM diaphragms are standard on all assemblies
  • 100% non-metallic wetted parts assures maximum chemical and temperature compatibility

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

TYPE 05 160 psi maximum pressure        
INSTRUMENT CONNECTION SIZES 02 1/4" NPT 04 1/2" NPT    
UPPER HOUSING MATERIAL PP PP        
DIAPHRAGM MATERIAL E EPDM-PTFE coated on process side        
PROCESS CONNECTION SIZES 02 1/4" NPT* 04 1/2" NPT    
LOWER HOUSING MATERIALS PV PVC PP PP KN PVDF

* Only available with 1/4" NPT Instrument Connection

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

PRODUCT SPECIFICATIONS
Seal type Threaded with non-replaceable diaphragm
Instruments Type Size Minimum Pressure Maximum Pressure
Gauges 2-1/2" to 6" 0 psig to 30 psig 0 psig to 160 psig
Transducers 0 psig to 30 psig 0 psig to 160 psig
Switches 0 psig to 30 psig 0 psig to 160 psig
Upper housing Type Non-continuous duty
Connections 1/4" NPT, 1/2" NPT
Materials PP, fiberglass reinforced
Diaphragm Size 1.77"
Displacement 8.9 ml
Materials EPDM, PTFE-coated
Lower housing Connections 1/4" NPT or 1/2" NPT
Materials PVC, PP or PVDF
Operating temperature   Operating temperature is determined by the temperature/pressure configuration. See Pressure/Temperature Diagram.

Options & Accessories

  • 1/4" NPT X 1/4" NPT Cooling Element (1/4" NPT X 1/4" NPT-CE)
  • 1/2" NPT X 1/2" NPT Cooling Element (1/2" NPT X 1/2" NPT-CE)
  • Works in combination with diaphragm seal to isolate instrument from high media temperatures
  • Recommended for process temperatures above 212 °F
  • Requires direct mounted system
  • Effective temperature reductions of 200 °F depending upon ambient conditions
  • High >212 °F process temperature, low < -40 °F process temperature
  • All Stainless Steel construction

WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

  • Glycerin (GY) *
  • Silicone (SL)
  • Halocarbon® (HL)
  • Neobee M20 (NB)
  • Mineral Oil (MO)
  • Propylene Glycol (PG)

* Not recommended for use in vacuum applications.

NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths.

View NOSHOK Distribution Manifolds

  • 5 ft. SS Armored Flexible Capillary, 1/4" NPT (AC-02-02-5) per ft. adder (AC-02-02-#)
  • 5 ft. SS Armored Flexible Capillary, 1/2" NPT (AC-04-04-5) per ft. adder (AC-04-04-#)
  • Stainless Steel capillaries available with or without Stainless Steel armor
  • Protects the instrument from high or low process temperatures
  • Allows remote mounting of pressure instrument(s)
  • Select the shortest capillary length possible, as changes in ambient temperature conditions may significantly affect the accuracy and response time of the instrument
  • Standard length 5', others available
  • Installation on analog gauges requires a gauge support and gauge adaptor, or other surface mounting provisions
  • Any level difference between the instrument and the seal will result in a pressure indication error; make sure to compensate for the level difference during calibration of the diaphragm seal assembly if the level difference is known
  • Filling options for capillaries
    • Silicone - specify to 10 or 20 feet (SL-C)
    • Halocarbon® - specify to 10 or 20 feet (HL-C)

WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov


WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

The NOSHOK All Non-Metallic Diaphragm Seal & Pressure Transmitter/Switch assembly is ideal for water, wastewater & chemical feed applications.

View NOSHOK All Non-Metallic Diaphragm Seal & Pressure Transmitter/Switch assembly

WARNING:This product can expose you to chemicals including Lead and Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

PT Transmitter Crossover Tool

Convert to PT Series