Dial Indicating

Home » Products » Pressure & Level » Pressure Gauges » Dial Indicating » 402/502 Series All Stainless Steel Extreme High Pressure Gauges, Dry & Liquid Filled

402/502 Series All Stainless Steel Extreme High Pressure Gauges, Dry & Liquid Filled

REQUEST A QUOTE
Download Literature
Water/
Wastewater
Oil & Gas
  • Corrosion-resistant dry or liquid-filled gauge for high pressure applications
  • Ranges from 0 psi to 30,000 psi through 0 psi to 85,000 psi
  • 4" and 6" gauge sizes
  • Solid front design with a blow out back in accordance to EN 837, 
  • S3 Safety Pattern
  • Stainless Steel case
  • NiFe alloy/316L Stainless Steel wetted parts
  • DIN 16001 compliant
  • Ideal for applications including pumps & compressors, high pressure processing, test equipment & systems and waterjet cutting

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SIZES 40 4" 60* 6" *        
CASE TYPES 402 Dry, bottom connection 502 Liquid filled, bottom connection
412 Dry, lower back connection    
PRESSURE RANGES 30000 0 psi to 30,000 psi 50000 0 psi to 50,000 psi 75000 0 psi to 75,000 psi    
40000 0 psi to 40,000 psi 60000 0 psi to 60,000 psi 85000 0 psi to 85,000 psi **    
SCALE OPTIONS psi psi single scale psi/kPa psi/kPa dual scale psi/kg/cm2 psi/kg/cm2 dual scale psi/bar psi/bar dual scale
CONNECTION SIZES *** 9/16-18 9/16"-18 UNF 2B high pressure cone 9/16-HPM 9/16″-18 UNF 2A left hand thread - Male      
OPTIONS BRSP Bayonet Ring Adjustable Set Pointer SL Silicone Fill ST Stainless Steel Tagging    
LM Laser Marking SP Red Set Pointer IA Increased Accuracy    
SSFF 304SS Front Flange        

Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information.

Note: Cleaning for Oxygen Service (O2) is available only for dry or HL filled gauges

   *    Bottom connection only
   **  Only available on 60-402 and 60-502 models, with ±1.6% accuracy
   *** Additional process connection sizes available

NOTES: See Standard Connection Sizes
Shaded portions of this part number example are not required unless a non-standard connection size or an option is needed.

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

  SERIES SPECIFICATIONS
Pressure ranges 402/502 Series (all) 0 psi to 30,000 psi through 0 psi to 85,000 psi
Accuracy ≤40,000 psi ±1.6% full scale (optional 1% increased accuracy)
≥50,000 psi ±1% full scale (85,000 psi is ±1.6% accuracy)
Temperature ranges* 402 & 412 Series Media -40 °F to 392 °F (-40 °C to 200 °C)
Ambient -40 °F to 140 °F (-40 °C to 60 °C)
502 Series Media -4 °F to 212 °F (-20 °C to 100 °C) Glycerin fill
Ambient -4 °F to 140 °F (-20 °C to 60 °C) Glycerin fill
Measuring element 402/502 Series (all) NiFe alloy
Connection 402/502 Series (all) 316L Stainless steel
Case 402/502 Series (all) Stainless Steel, solid front with blowout back
Cover ring 402/502 Series (all) Stainless Steel bayonet ring
Lens 402/502 Series (all) Laminated safety glass
Pointer 402/502 Series (all) Black finished aluminum
Dial 402/502 Series (all) Aluminum, white background with black scale.
Single scale psi. UV resistant
Movement 402/502 Series (all) Stainless steel with highly polished bearing surfaces
Fill liquid 502 Series
(Bottom connected only)
Glycerin

*  For every 68 °F (20 °C) shift in temperature from which the gauge is calibrated, the user can experience up to ±0.4

Working Pressure Limitations

Dynamic Pressure
The working pressure should be limited to 65% of the dial range.

Static Pressure 
The working pressure, where no sharp fluctuations occur, should be limited to 75% of the dial range

Options & Accessories

AVAILABLE

  • Red Set Pointer (SP)
  • Maximum Indicating Pointer (MIP)
  • Bayonet Ring Adjustable Set Pointer (BRSP)
  • 304 SS Front Flange (SSFF)
  • Laser Marking (LM)
  • Stainless Steel Tagging (ST)
  • Increased Accuracy from ±1.6% to ±1.0% (IA)

CONSULT FACTORY

  • 9/16-18 UNF Male Process Connection

CERTIFICATES

  • Certified Calibration (CC)                                       
  • Cleaning for Oxygen Service (O2)                     

NOTE: Consult Factory for additional Pressure Range, Dial Scale Unit and Connection availability.

Prop 65

WARNING:This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

  • Certificate of Cleaning (COCL)
  • Certificate of Conformance (COC)

AVAILABLE

  • Red Set Pointer (SP)
  • Maximum Indicating Pointer (MIP)
  • Bayonet Ring Adjustable Set Pointer (BRSP)
  • 304 SS Front Flange (SSFF)
  • Laser Marking (LM)
  • Stainless Steel Tagging (ST)
  • Increased Accuracy from ±1.6% to ±1.0% (IA)

CONSULT FACTORY

  • 9/16-18 UNF Male Process Connection

CERTIFICATES

  • Certified Calibration (CC)                                       
  • Cleaning for Oxygen Service (O2)                     

NOTE: Consult Factory for additional Pressure Range, Dial Scale Unit and Connection availability.

Prop 65

WARNING:This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

  • Certificate of Cleaning (COCL)
  • Certificate of Conformance (COC)

AVAILABLE

  • Red Set Pointer (SP)
  • Maximum Indicating Pointer (MIP)
  • Bayonet Ring Adjustable Set Pointer (BRSP)
  • 304 SS Front Flange (SSFF)
  • Laser Marking (LM)
  • Stainless Steel Tagging (ST)
  • Increased Accuracy from ±1.6% to ±1.0% (IA)

CONSULT FACTORY

  • 9/16-18 UNF Male Process Connection

CERTIFICATES

  • Certified Calibration (CC)                                       
  • Cleaning for Oxygen Service (O2)                     

NOTE: Consult Factory for additional Pressure Range, Dial Scale Unit and Connection availability.

Prop 65

WARNING:This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

  • Certificate of Cleaning (COCL)
  • Certificate of Conformance (COC)

AVAILABLE

  • Red Set Pointer (SP)
  • Maximum Indicating Pointer (MIP)
  • Bayonet Ring Adjustable Set Pointer (BRSP)
  • 304 SS Front Flange (SSFF)
  • Laser Marking (LM)
  • Stainless Steel Tagging (ST)
  • Increased Accuracy from ±1.6% to ±1.0% (IA)

CONSULT FACTORY

  • 9/16-18 UNF Male Process Connection

GAUGE FILL OPTIONS

  • Silicone (SL)

CERTIFICATES

  • Certified Calibration (CC)                                        
  • Cleaning for Oxygen Service (O2)                     

NOTE: Consult Factory for additional Pressure Range, Dial Scale Unit and Connection availability.

Prop 65

WARNING:This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

  • Certificate of Cleaning (COCL)
  • Certificate of Conformance (COC)

AVAILABLE

  • Red Set Pointer (SP)
  • Maximum Indicating Pointer (MIP)
  • Bayonet Ring Adjustable Set Pointer (BRSP)
  • 304 SS Front Flange (SSFF)
  • Laser Marking (LM)
  • Stainless Steel Tagging (ST)
  • Increased Accuracy from ±1.6% to ±1.0% (IA)

CONSULT FACTORY

  • 9/16-18 UNF Male Process Connection

GAUGE FILL OPTIONS

  • Silicone (SL)

CERTIFICATES

  • Certified Calibration (CC)                                        
  • Cleaning for Oxygen Service (O2)                     

NOTE: Consult Factory for additional Pressure Range, Dial Scale Unit and Connection availability.

Prop 65

WARNING:This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

  • Certificate of Cleaning (COCL)
  • Certificate of Conformance (COC)

NOSHOK offers multiple assembly options to meet your specific system requirements. Consult factory to discuss your customized solution.

NOSHOK offers a wide variety of standard & elevated pressure, and reduced pressure replaceable and non-replaceable diaphragm seals, designed to isolate and/or protect the pressure measuring instrument from corrosive, viscous, contaminated or very high temperature process media.

View NOSHOK's Diaphragm Seal offering

NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths.

View NOSHOK Distribution Manifolds

  • Dual scale metric dials in psi/bar, psi/kPa and psi/kg/cm2 
  • Other scales are available for specific sizes and ranges, such as single scale bar and kPa, refrigerant scales and altitude scales
  • Customized special dials such as non-standard metric scale, tons of ram, lbs. of force, etc. are available in small quantities (as few as one piece) on some NOSHOK gauges

Please consult the factory for availability.

  • Resist clogging and are self-cleaning
  • Five different sized pistons included with each snubber to ensure the correct amount of snubbing for virtually every application
  • Available in Brass and 316 Stainless Steel in 1/4" NPT, 1/2" NPT or SAE J1926-3: 7/16-20
  • Weight approximately 0.2 lb. for 1/4" & 7/16", and approximately 0.4 lb. for 1/2"​​​​​​

Specifications

WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov


WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

  • Cost effective solution to protect expensive instrumentation
  • Increases gauge readability by smoothing out pressure surges, pulsations and spikes
  • 5 basic elements available for each snubber to accommodate specific application needs
  • Snubbing action achieved by utilizing a corrosion resistant 316 Stainless Steel sintered porous element
  • Exotic materials or intermediate disc grades available
  • Provides long service life with no moving parts to wear out
  • Weight approximately 0.2 lb. for 1/4" & 7/16", and approximately 0.4 lb. for 1/2

Specifications

Dimensions

Replacement Disc Options

WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov


WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

  • Protect the instrument from the damaging effects of high temperature steam
  • Recommended for use in all steam applications
  • Available in 1/4" and 1/2" NPT sizes in welded steel, welded 316 Stainless Steel or seamless 316 Stainless Steel with ratings to 3,800 psi @ 850 ºF

Specifications

Dimensions

Steam Syphons Temperature 1/4" NPT vs. Pressure charts

Steam Syphons Temperature 1/2" NPT vs. Pressure charts

WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov


WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

  • Temperature ratings: 15,000 psi @ 200 °F and 3,000 psi @ 1,000 °F
  • Used with gauges and gauge valves to adjust the line of sight
  • Rotates 360° to allow the connected instrument to be positioned in the desired direction
  • The pressure connection is achieved with a tapered cone style compression fitting simply by tightening the swivel hex nut
  • All 316 Stainless Steel construction
  • Standard with 1/2" NPT male process – 1/2" NPT female instrument connections
  • Also available with 1/4" NPT connections, same specifications apply
  • Weight approximately 0.8 lb.

Swivel Adaptor Dimensions


WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

WARNING:This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Pressure Gauges

Frequently Asked Questions

A: A fill plug seals the fill hole in a pressure gauge case. On liquid filled pressure gauges, a ventable fill plug is used to relieve internal case pressures that occur due to thermal expansion of the fill fluid. In non-filled dry gauges, a non-ventable fill plug is used to occasionally drain the interior of the case from condensate or relieve internal case pressures. Ventable fill plugs incorporate a vent pin to open and close a hole for relieving internal case pressures and do not have to be removed from the case hole like non-ventable fill plugs.

A: Overpressure ratings are specific to the gauge type, pressure range and accuracy ratings of the gauge. Normal overpressure protection can range from 1.1 times to 1.3 times the full scale pressure depending on the gauge selected. NOSHOK gauges comply to the EN-837-1 and ASME B40.100 standards in regards to overpressure protection. When selecting a pressure gauge, it is recommended that the normal system pressure be maintained around half of the full range of the gauge as to avoid overpressure conditions.

A: A Maximum Indicating Pointer (MIP), also commonly referred to as a Tell Tale Pointer, adds an additional error to the pressure gauge due to the increase load on the bourdon tube. The lower the pressure range, the higher the error. Typically 1%. Consult factory.

A: Certified Calibrations provide the user with a serial numbered gauge along with a calibration certificate that it has been certified in accordance to the pressure gauge standard with instruments that are traceable to NIST with accuracies of at least 4 to 1.

A: A Certificate of Conformance is a formal statement on company letterhead stating that an instrument complies with a particular standard and/or specification. It contains the signatures of the required personnel. These Certificates are often needed to show industry inspectors that a system and its components are in compliance.

A: NOSHOK pressure gauges require little or no calibration within the Warranty period. Some applications may be more aggressive than others, resulting in an increased frequency in the need for calibration. The environmental limitations for the pressure gauge series should be observed in all cases. Gauges used in situations outside these requirements may result in inaccuracies, premature wear and/or failure of the gauge and would require additional maintenance. The frequency of calibration, therefore, is best left to the user to determine.

A: Orifices are a type of snubber. On pressure systems that have rapidly increasing or decreasing pressure spikes, orifices lessen the effects of these energy pulses by blocking the wave energy using restricted flow. They are recommended in dynamic pressure applications with mild pressure spikes.

A: A diaphragm is used to isolate and protect the instrument from the process media. Damaging process media may include corrosives, particulates, temperatures, or any state that is not suitable for direct contact with the measuring element. Diaphragms indirectly transmit system pressures by segregating the process pressure with a thin flexible membrane that in turn transfers the pressure through a fill fluid to the instrument. Diaphragms are often used in conjunction with capillaries to further distance the instrument from the process media. Capillary tubes transmit the diaphragm fill fluid to the instrument. Capillary tubes come in several lengths and provide the user a means to measure in a remote location and may also act as heat dissipaters in high temperature applications.

A: Primarily, in applications that have vibrations or pulsations, liquid filling enables reading the dial pointer by dampening the movement. Liquid filling should be considered in any system that has high dynamic operating conditions. In general, liquid filling helps extend the life of a gauge. It reduces damaging resonance induced fracturing, reduces frictional wear, prevents aggressive ambient air from entering, prevents condensation formation, and improves reliability.

A: Temperature changes affect the stiffness of a bourdon tube. The stiffness change is produced by a combination of changes in the elastic (Young's) modulus and a change in linear dimensions due to linear expansion and contraction. The error caused by temperature change will follow the approximate formula: ± 0.04 x (t2 ñ t) % of of the span.

A: The pressure range of a gauge should be a minimum of 10 percent over the maximum working pressure in static conditions with no pressure fluctuations. In dynamic conditions, the gauge range should be a minimum of 40 percent over the maximum working pressure. Ideally, the pressure gauge range should be selected for a midscale reading during normal operating pressures.

A: Accuracy is the difference between the true value and the gauge indication expressed as a percent of the gauge span. It is determined by comparing a gauge indication to a known standard or certified true value and combines the effects of method, observer, apparatus, and environment. Accuracy error also includes hysteresis and repeatability errors. An ASME B40.1 class B gauge has three accuracies. For example, a 3-2-3 percent of span designation stands for 3 percent in the first quarter of the scale, 2 percent in the middle half of the scale and 3 percent in the upper quarter of the scale.

A: Lens materials include Instrument Glass, Laminated Safety Glass, Tempered Glass, and plastic. Glass lenses are used for abrasion, chemical and wear resistant properties. Laminated safety glass reduces the possibility of shattering if the bourdon tube ruptures. Tempered glass is 2 to 5 times stronger than plain glass. Plastic lenses are used for impact, corrosion and chemical resistance. Special attention should be paid to the temperature and corrosive environments. Polycarbonate is selected for its superior impact resistance, acrylic for its clarity and scratch resistance and Homalite for its superior chemical resistance. In general, gauges with plastic lenses should remain below 140 degrees Fahrenheit.

A: Pigtail syphons should be used in steam applications and systems that contain superheated vapor. The pigtail buffers the instrument from the damaging effects of high temperature steam by holding system fluid in the coil to provide a steam trap for the fluid to condensate and dissipate the heat.

A: Cleaning for Oxygen (O2) service is performed on gauges that are used on oxygen service or oxidizing media applications. The cleaning removes all hydrocarbons, such as oil and grease, that can react violently, resulting in explosions, fire, and injury to personnel and property. Gauges cleaned for Oxygen service can be used in any application that requires the cleanliness level associated with oxygen cleaned gauges. Glycerin filled gauges cannot be used on oxygen systems or on other oxidizing media.

A: Glycerin is the most common fill fluid. Because of its unique fluid properties, Glycerin has become the standard for liquid filled gauges. Glycerin's clarity, viscosity, stability, cost, solubility and low toxicity make it an ideal fluid for many applications. Mineral oils and silicone fluids are used when temperature extremes, chemical compatibility or viscosity fall outside of Glycerin use. Halocarbon is an inert fluid that is compatible with chlorine, oxygen service and some high temperature applications. Glycerin is not compatible with strong oxidizers such as oxygen, chlorine, hydrogen peroxide or nitric acid. Glycerin and silicone are explosive in contact with chlorine. Halocarbon is explosive in contact with aluminum and magnesium.

A: The ASME B40.100 (formerly ASME B40.1) and EN 837-1 are both standards for pressure gauges, but they serve different regions and regulatory frameworks. ASME B40.100 is the U.S. standard for dial-type, elastic-element pressure gauges, providing guidelines for design, accuracy, performance, and testing. Primarily used in North America, it includes similar technical requirements to EN 837-1 within a mandatory appendix. EN 837-1, on the other hand, is the European standard specifically for Bourdon tube pressure gauges, enforcing strict requirements for dimensions, metrology, and testing to ensure compliance within the European Union. While both standards cover similar aspects of pressure gauge design and performance, EN 837-1 is a regulatory requirement for products sold in Europe, often necessary for CE marking, whereas ASME B40.100 serves as an industry guideline aligned with ANSI-approved U.S. standards.

A: Throttle devices limit the flow to the pressure instrument. They are a type of snubber.

A: The tip motion of a bourdon tube is translated to rotary motion of a pointer by a linkage and sector gear acting on the pointer pinion gear. Stop pins limit the movement of the bourdon tube, sector or pointer rotation in over and under pressure conditions that would otherwise move the pointer pinion off the sector gear and damage the gauge.

More questions? Contact NOSHOK Customer Support at info@noshok.com