Use the PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to the new PT Series transmitters.
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SERIES | SV | Stabilized connector with integral block valve | ||
MATERIALS | C | Steel | S | Stainless steel |
CONNECTOR TYPES | 1 | Stabilized connector pair with integral valve* | 2 | Stabilized connector pair with integral valve, flange adaptor** |
OPTIONS† | DK1 | One Piece Dielectric Gasket, Pair | DK2 | PTFE Gasket with Dielectric Shim, Pair |
DK1-SS | One Piece Dielectric Gasket, Pair w/SS Bolts | DK2-SS | PTFE Gasket with Dielectric Shim, Pair w/SS Bolts |
† For more information on Dielectric Kits, see below.
* For flat installations (orifice fitting)
** For Round installation (orifice flange)
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SPECIFICATIONS | |
Materials | Zinc-nickel plated Carbon Steel, 316 stainless steel* |
Bolts | Carbon Steel |
Connection | 1/2" NPT-flange |
Pressure rating | 6,000 psi at 200 °F |
Orifice | 0.375" |
Flow coefficient | Cv 3.0 |
Stem seal & type | All 316 Stainless Steel stems with FKM o-ring and PTFE back-up ring below the threads |
Weight | Approximately 10.6 lb. (pair) |
* All 316SS products meet the requirements of NACW MR0175/ISO 15156-3
Dielectric Kits are designed to maintain the integrity and reliability of the pipeline and piping system through safety and corrosion protection. Dielectric Kits provide a non-conductive barrier between the process piping and the instrument and isolate components from the effects of electrical current. By eliminating metal-to-metal contact, current is halted to prevent corrosion and aid in the cathodic protection of the system.
DK1
DK2
Specifications:
All 316SS products meet the requirements of NACE MR0175/ISO 15156-3.
WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
The NOSHOK Direct Connect Assembly provides an installation that keeps the meter close to the orifice taps for accurate flow measurements.
View the NOSHOK Direct Connect Assembly
WARNING:This product can expose you to chemicals including Lead and Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov