SERIES | 300V | 300 Vacuum Series | 300H | 300 High Pressure Series | |
300L | 300 Low Pressure Series | ||||
SWITCH FUNCTION | 1 | SPST, Normally open | 3 | SPDT | |
2 | SPST, Normally closed | ||||
PROCESS CONNECTION | 1 | 1/8″ NPT male | 33 | G 1/8B | |
2 | 1/4" NPT male | 45 | 7/16-20 SAE Male, Non-Adjustable | ||
10 | G 1/4B | ||||
300V VACUUM PRESSURE SWITCH ADJUSTMENT RANGES (Max. working pressure) | 5/28-vac | -5 inHg to -28 inHg (350 psig) | |||
300L LOW PRESSURE SWITCH ADJUSTMENT RANGES (Max. working pressure) | 3/7 | 3 psig to 7 psig (870 psig) | 7/120 | 7 psig to 120 psig (870 psig) | |
3/15 | 3 psig to 15 psig (870 psig) | 15/200 | 15 psig to 200 psig (870 psig) | ||
3/30 | 3 psig to 30 psig (870 psig) | 15/230 | 15 psig to 230 psig (870 psig) | ||
7/70 | 7 psig to 70 psig (870 psig) | 30/290 | 30 psig to 290 psig (870 psig) | ||
300H HIGH PRESSURE SWITCH ADJUSTMENT RANGES (Max. working pressure) | 100/220 | 100 psig to 220 psig (5,000 psig) | 145/2320 | 145 psig to 2,320 psig (5,000 psig) | |
145/435 | 145 psig to 435 psig (5,000 psig) | 300/2900 | 300 psig to 2,900 psig (5,000 psig) | ||
145/1160 | 145 psig to 1,160 psig (5,000 psig) | 300/3600 | 300 psig to 3,600 psig (5,000 psig) | ||
145/1750 | 145 psig to 1,750 psig (5,000 psig) | 450/4600 | 450 psig to 4,600 psig (5,000 psig) | ||
ELECTRICAL CONNECTIONS† | 1 | 36" Cable attached to option 8 | 100 | Deutsch 2-Pin Male (DT04-2P)*, ** | |
8 | DIN EN 175301-803 Form A | 101 | Deutsch 3-Pin Male (DT04-3P)* | ||
25 | M12 x 1 4-Pin | 103 | Deutsch 2-Pin Female Socket (DT06-2S)*, ** | ||
36 | 3’ Integral Cable | 104 | Deutsch 3-Pin Female Socket (DT06-3S)* | ||
66 | Deutsch Integral 2-Pin (DT04-2P) ** | 110 | Weatherpack Tower, 3-Pin Female* | ||
96 | Weatherpack Tower, 2-Pin Female*, ** | 111 | Weatherpack Tower, 3-Pin Male* | ||
97 | Weatherpack Tower, 2-Pin Male*, ** | 112 | Weatherpack Shroud, 3-Pin Female* | ||
98 | Weatherpack Shroud, 2-Pin Female*, ** | 113 | Weatherpack Shroud, 3-Pin Male* | ||
99 | Weatherpack Shroud, 2-Pin Male*, ** | ||||
OPTIONS *** | EP | EPDM Diaphragm (-40/212 °F) | VT | FKM Diaphragm (0/250 °F) | |
HNBR | Low Temp Nitrile (-40/176 °F) | SS | 316 SS Wetted Materials | ||
SP | Factory Adjusted Switch Point |
Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information.
* Options attached to 18” cable
** For SPST only*** Not all options are available for all ranges, consult factory
† Other electrical connections available, consult the factory
If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.
SPECIFICATIONS | |
Switching parameters Function Contact rating Repeatability Hysteresis Contact material Frequency |
SPST or SPDT 6A @ 125/250 Vac 6A @ 12/24 Vdc 2% of full set point range at 70 °F Adjustable, view charts Solid Silver, self-cleaning Max. 100 cycles/min |
Switch type | Snap action with adjustable hysteresis |
Pressure ranges | -5 inHg to -28 inHg (350 psig) through 450 psig to 4,600 psig (5,000 psig) |
Service life | >1,000,000 load cycles |
Temperature ranges | Media -4 °F to 176 °F (-20 °C to 80 °C) Ambient -4 °F to 176 °F (-20 °C to 80 °C) Storage -4 °F to 176 °F (-20 °C to 80 °C) |
Proof pressure | 870 psig or 5,000 psig depending on adjustment range |
Measuring element | NBR |
Housing material | Zinc-nickel plated Steel |
Environmental rating | IP65 - DIN EN 175301-803 Form A IP67 - All others |
Weight | Approximately 0.2 lb |
NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths.
View NOSHOK Distribution Manifolds
WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Steam Syphons Temperature 1/4" NPT vs. Pressure charts
Steam Syphons Temperature 1/2" NPT vs. Pressure charts
WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WARNING:This product can expose you to chemicals including Lead and Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov