Industrial

Home » Products » Pressure & Level » Pressure Transducers & Transmitters » Industrial » PT40 Series High Accuracy Fixed Range Transmitters & Transducers

PT40 Series High Accuracy Fixed Range Transmitters & Transducers

REQUEST A QUOTE VIEW BY PART NUMBER
Download Literature
PT Series
NOSHOK 100, 200, 300 and 615 Series transmitters are replaced with the new PT Series, an enhanced and expanded portfolio of fixed range general purpose pressure transmitters that provides significant performance improvements and options.
Learn more →

New PT Crossover Tool Video

NOSHOK Advanced Technology General Purpose Fixed Range & Intelligent Pressure Transmitters

  • Gauge, compound, absolute and vacuum ranges from 2 psig to 15,000 psig
  • Premium accuracy
  • Field adjustable offset and span
  • Current and voltage outputs available 
  • 316 and 13-8PH Stainless Steel wetted parts
  • CE compliant to suppress RFI, EMI and ESD
  • RoHS compliant
     

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SERIES PT40              
PRESSURE
RANGES
15psiv -15 psig to 0 psig 10psig 0 psig to 10 psig 750psig 0 psig to 750 psig 15000psig 0 psia to 15,000 psig
15psic -15 psig to 15 psig 15psig 0 psig to 15 psig 1000psig 0 psig to 1,000 psig 15psia 0 psia to 15 psia
30psic -15 psig to 30 psig 30psig 0 psig to 30 psig 1500psig 0 psig to 1,500 psig 30psia 0 psia to 30 psia
60psic -15 psig to 60 psig 60psig 0 psig to 60 psig 2000psig 0 psig to 2,000 psig 60psia 0 psia to 60 psia
100psic -15 psig to 100 psig 100psig 0 psig to 100 psig 3000psig 0 psig to 3,000 psig 100psia 0 psia to 100 psia
200psic -15 psig to 200 psig 150psig 0 psig to 150 psig 4000psig 0 psig to 4,000 psig 150psia 0 psia to 150 psia
300psic -15 psig to 300 psig 200psig 0 psig to 200 psig 5000psig 0 psig to 5,000 psig 200psia 0 psia to 200 psia
2psig 0 psig to 2 psig 300psig 0 psig to 300 psig 6000psig 0 psig to 6,000 psig 300psia 0 psia to 300 psia
3psig 0 psig to 3 psig 500psig 0 psig to 500 psig 7500psig 0 psig to 7,500 psig    
5psig 0 psig to 5 psig 600psig 0 psig to 600 psig 10000psig 0 psig to 10,000 psig    
psiv = vacuum gauge pressure   psic = compound gauge pressure   psig = gauge pressure
psia = absolute pressure   Other ranges available upon request
Note: Front flush connection is available for pressure ranges up to 0 psig to 8,000 psig
ACCURACIES 1 ±0.25% (of span, non-linearity, BFSL per IEC
61298-2 at reference conditions)
2 ±0.125% (of span, non-linearity, BFSL per IEC
61298-2 at reference conditions)
OUTPUT SIGNALS 1 4 mA to 20 mA, 2-wire   3 1 Vdc to 5 Vdc, 3-wire  
2 0 Vdc to 5 Vdc, 3-wire   5 0 Vdc to 10 Vdc, 3-wire
PROCESS
CONNECTIONS
1/8" NPT male SAE J1926-1:7/16-20 female 13  G 1 B Front flush (For ranges with span <30 psi)
1/4" NPT male 10 G1/4B EN837 45  7/16-20 SAE J514 FIG 34B (Non-Adjustable)
8 1/2" NPT male 11  G 1/2B Front flush (For ranges with span ≥30 psi) 83  G 1/2 B EN837
      Other connections available upon request    
ELECTRICAL
CONNECTIONS
2 4-pin Bayonet 17 DIN EN 175301-803 Form C w/ 3 ft. cable
3 6-pin Bayonet 18 DIN EN 175301-803 Form A w/ 3 ft. cable
7 DIN EN 175301-803 Form C 25 M12 x 1 (4-pin)
8 DIN EN 175301-803 Form A 36 3 ft. Integral cable
14 DIN EN 175301-803 Form A w/ 1/2" NPT female conduit 70 DIN EN 175301-803 Form C w/o mating connector
16 1/2" NPT conduit w/ 3 ft. cable 80 DIN EN 175301-803 Form A w/o mating connector
OPTION ST8 Threaded Orifice (0.8 mm)        

Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information.

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

SPECIFICATIONS
Output signals 4 mA to 20 mA, 2-wire; 0 Vdc to 5 Vdc, 0 Vdc to 10 Vdc, 1 Vdc to 5 Vdc,3-wire
Pressure ranges Gauge, compound, absolute and vacuum ranges from 2 psi to 15,000 psi
Accuracy* ±0.25% of span, optional ±0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions
Adjustment ± 10% full scale for zero and span
Response time Less than 1 ms (between 10% and 90% full scale)
Service life >100 million load cycles
Temperature ranges* Compensated:
Media:
Ambient:
Storage:
32 °F to 176 °F (0 °C to 80 °C)
-22 °F to 212 °F (-30 °C to 100 °C)
-22 °F to 185 °F (-30 °C to 85 °C)
-40 °F to 212 °F (-40 °C to 100 °C)
Power requirement* 10 Vdc to 30 Vdc:   
  

14 Vdc to 30 Vdc:
4 mA to 20 mA, 2-wire
1 Vdc to 5 Vdc, 3-wire
0 Vdc to 5 Vdc, 3-wire
0 Vdc to 10 Vd, 3-wire
Proof pressure <300 psi:
300 - 10,000 psi:
>10,000 psi:
3 times full scale
2 times full scale
1.5 times full scale
Burst pressure <300 psi:
300 - 10,000 psi:
>10,000 psi:
5 times full scale
4 times full scale
3 times full scale
Measuring element 316 Stainless Steel:
13-8PH Stainless Steel:
Vacuum through 300 psi
≥500 psi
Process connection 316 Stainless Steel
Housing material 316 Stainless Steel
Environmental rating IP65: DIN EN 175301-803 Form C, DIN EN 175301-803 Form A
IP67: 4-pin Bayonet, 6-pin Bayonet, 1/2" NPT conduit, M12 x 1 (4-pin),
Integral cable
Electromagnetic rating CE compliant to EMC norm EN 61326:2014/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, overvoltage and short circuit protection
Shock 1,000 g’s according to IEC 60068-2-27
Vibration 20 g’s according to IEC 60068-2-6
Weight Approximately 7.5 oz.

*See user manual for detailed specifications

Options & Accessories

WARNING:This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Transducers & Transmitters

Frequently Asked Questions

A: In many industrial applications, the terms pressure transmitter, pressure transducer and pressure sensor are used interchangeably. Traditionally, a transmitter referred to an instrument with a current output signal such as 4 mA to 20 mA, and a transducer referred to an instrument with a voltage output signal such as 0 Vdc to 10 Vdc. Today, all three terms are commonly used to describe electronic pressure measurement devices, so a NOSHOK pressure transmitter or transducer is often considered a type of pressure sensor.

A: When these terms originated there was a distinctive difference between the two. A transmitter was referred to as an instrument with a current signal, for example 4 mA to 20 mA, and a transducer was referred to as an instrument with a voltage signal, for example 0 Vdc to 10 Vdc. As time has progressed these terms are now commonly interchanged for reference to either output signal.

A: Proof pressure, which is higher than the full scale pressure point, is the limit that you can go to without affecting the performance and calibration of the transducer. The burst pressure, on the other hand, is the limit that you can go to before there is pressure chamber rupture and damage. An overload limit specification used sometimes means that proof and burst ratings are identical.

A: Radio Frequency Interference (RFI) and Electromagnetic Interference (EMI) refer to the effects electrical noise can have on instruments. RFI frequently comes from hand held walkie-talkies and EMI comes from AC motors in the vicinity of the instrument. ESD, or Electrostatic Discharge, comes from many sources including the application itself. CE compliant transmitters and transducers incorporate protection techniques and components to minimize most of the interference.

A: Most diaphragm seals can be used with pressure transducers and transmitters. The key is to assemble and fill the seal properly, being careful not to entrap air in the fill fluid.

A: The steam syphon is necessary in steam pressure applications. It is important to isolate the transmitter sensing diaphragm from the high temperature encountered with steam pressure applications.

A: As with other pressure measurement instruments including gauges, pressure pulsations and spikes are issues with pressure transmitters. Whenever the pressure of an incompressible fluid is measured, there is the potential for pulsations and spikes, which can damage pressure transmitters. An orifice installed in the pressure connection by NOSHOK can protect the transmitter from damage. Where there is the possibility of clogging the small orifice, an attachable piston snubber is recommended.

A: All pressure measurements are inherently differential in theory. Gauge pressure is referenced to ambient atmospheric pressure, and absolute pressure is referenced to a vacuum contained in an evacuated chamber within the transmitter. The level measurement is also a differential measurement, with its reference to ambient atmospheric pressure. In order for the submersible level measurement to be referenced to atmospheric, the cable contains a vent tube which runs the complete length of the cable and vents to atmospheric pressure at the junction box connection, which is out of the liquid.

A: The transmitter measures the hydrostatic pressure produced by the liquid level higher than the point where the instrument is located. The higher the liquid, the higher the pressure.

A: Voltage output transducers are available with a fourth connection which is electrically the same as the power supply common to connect to wiring configurations that require it.

A: A smaller diaphragm is less easily damaged, and positioning the sensors directly behind the diaphragm minimizes fill fluid and enables active temperature compensation directly at the point of measurement.

A: A turndown ratio, also commonly known as rangeability, refers to the ratio between the full-scale range and the minimum point of measure, indicating the range in which an instrument can accurately measure the media. For example, if a pressure transmitter has a maximum calibration range of 0 to 300 psi and a turndown ratio of 10:1, the span can be adjusted anywhere between 0 to 30 psi and 0 to 300 psi. The higher the turndown ratio, the higher the rangeability, which can also help minimize required inventory.

More questions? Contact NOSHOK Customer Support at info@noshok.com