Non-Replaceable

Home » Products » Diaphragm Seals » Non-Replaceable » Type 25/25H Standard & Elevated Pressure, Non-Replaceable Diaphragm Seals

Type 25/25H Standard & Elevated Pressure, Non-Replaceable Diaphragm Seals

REQUEST A QUOTE VIEW BY PART NUMBER
Download Literature
Water/
Wastewater
  • Designed to isolate the pressure measuring instrument from corrosive or viscous process media
  • Utilize an all welded, all metallic housing design to eliminate potential leak paths
  • For use with gauges with dial sizes of 2-1/2" and smaller, and pressure ranges no less than 100 psig
  • Housing and diaphragm offered in a variety of materials to suit most applications
  • A flushing port is available to clean wetted areas and prevent process media build up
  • Consider instrument size, pressure range, media composition, ambient and operating temperature, and maximum working pressure when selecting
  • Capillaries and cooling elements are available for elevated process temperatures, see options & accessories below
  • Fill fluid must be compatible with process media; i.e. Glycerin may become volatile in conjunction with a strong oxidizing agent such as chlorine, forms of  oxygen or peroxide and nitric acids

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

TYPES 25 (2,500 psi) 25H (5,000 psi)    
INSTRUMENT CONNECTION SIZES 02 1/4" NPT 04 1/2" NPT    
UPPER HOUSING MATERIALS H Hastelloy C-276 M Monel 400 P Carpenter 20 S 316 Stainless steel
DIAPHRAGM MATERIALS H Hastelloy C-276 M Monel 400 * P Carpenter 20 * S 316 Stainless steel
PROCESS CONNECTION SIZES 02 1/4" NPT 04 1/2" NPT    
LOWER HOUSING MATERIALS H Hastelloy C-276 M Monel 400 P Carpenter 20 S 316 Stainless steel
OPTIONAL FLUSHING CONNECTIONS 1F 1/8" NPT 2F 1/4" NPT    
OPTIONAL FLUSH PORT PLUG p (Flush port plug will match lower housing material)        

* When selecting a Monel or Carpenter 20 Diaphragm, the upper and lower housing must be the same material.

If you are viewing on a smaller screen or with screen zoom, please use the horizontal scroll bar at the bottom of this table to see all information.

PRODUCT SPECIFICATIONS
Seal type Threaded with welded diaphragm
Instruments Type Size Minimum Pressure Maximum Pressure
Gauges 2-1/2" 0 psig to 100 psig 0 psig to 2,500 psig (25H - 5,000 psig)
Transducers 0 psig to 60 psig 0 psig to 2,500 psig (25H - 5,000 psig)
Switches 0 psig to 60 psig 0 psig to 2,500 psig (25H - 5,000 psig)
Upper housing Type Non-continuous duty
Connections 1/4" NPT, 1/2" NPT
Materials 316 Stainless Steel
Diaphragm Size 1.28"
Displacement 400 mm3
Materials 316 Stainless Steel (Exotic materials available on request)
Lower housing Connections 1/4" NPT, 1/2" NPT, 3/4" NPT, 1" NPT, 1-1/4" NPT, 1-1/2" NPT
Materials 316 Stainless Steel (Exotic materials available on request)
Flushing port Optional 1/8" NPT and 1/4" NPT
Operating temperature   Operating temperature is determined by the temperature/pressure
configuration. See Material Temperature table.

Options & Accessories

  • 1/4" NPT X 1/4" NPT Cooling Element (1/4" NPT X 1/4" NPT-CE)
  • 1/2" NPT X 1/2" NPT Cooling Element (1/2" NPT X 1/2" NPT-CE)
  • Works in combination with diaphragm seal to isolate instrument from high media temperatures
  • Recommended for process temperatures above 212 °F
  • Requires direct mounted system
  • Effective temperature reductions of 200 °F depending upon ambient conditions
  • High >212 °F process temperature, low < -40 °F process temperature
  • All Stainless Steel construction

WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

  • Glycerin (GY) *
  • Silicone (SL)
  • Halocarbon® (HL)
  • Neobee M20 (NB)
  • Mineral Oil (MO)
  • Propylene Glycol (PG)

* Not recommended for use in vacuum applications.

NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths.

View NOSHOK Distribution Manifolds

  • 5 ft. SS Armored Flexible Capillary, 1/4" NPT (AC-02-02-5) per ft. adder (AC-02-02-#)
  • 5 ft. SS Armored Flexible Capillary, 1/2" NPT (AC-04-04-5) per ft. adder (AC-04-04-#)
  • Stainless Steel capillaries available with or without Stainless Steel armor
  • Protects the instrument from high or low process temperatures
  • Allows remote mounting of pressure instrument(s)
  • Select the shortest capillary length possible, as changes in ambient temperature conditions may significantly affect the accuracy and response time of the instrument
  • Standard length 5', others available
  • Installation on analog gauges requires a gauge support and gauge adaptor, or other surface mounting provisions
  • Any level difference between the instrument and the seal will result in a pressure indication error; make sure to compensate for the level difference during calibration of the diaphragm seal assembly if the level difference is known
  • Filling options for capillaries
    • Silicone - specify to 10 or 20 feet (SL-C)
    • Halocarbon® - specify to 10 or 20 feet (HL-C)

WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov


WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov


WARNING:This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

Diaphragm Seals

Frequently Asked Questions

A: Utilizing diaphragm seals with instruments is recommended when instrumentation is to be used in corrosive process media or extreme temperature media environments. Important factors to consider when selecting the correct diaphragm seal for a specific application include the instrument's location, the instrument's process connection size and type, process pressure and temperature limits, and any nontechnical fill fluid limitations such as nontoxic fill fluids for sanitary applications.

A: Process media compatibility is a key factor to consider when selecting a diaphragm seal fill fluid. Process media temperature should also be taken into account as all fill fluids expand or contract with temperature variations. The fill fluid viscosity and density are directly related to the measurement response time; the more viscous the fill fluid, the longer the response time, and a higher density fill fluid may affect mounting as well. Common diaphragm seal fill fluids include glycerin, silicone oils and halocarbon, but NOSHOK offers many more options including Neobee M20, mineral oil and propylene glycol for specialized applications. Glycerin should not be used for vacuum and compound gauges, or where a capillary is used between the instrument and diaphragm seal.

A: A diaphragm seal is designed to provide protection from corrosive, viscous, contaminated or very high temperature process media to valuable instrumentation. The pressure measuring element of the measuring device and the instrument connection port are filled with a suitable liquid using vacuum filling technology, making pressure measurement a direct and simple process. Pressure, when applied to the surface of the diaphragm, causes a pressure increase in the fill fluid which is then transferred to the attached pressure gauge, transducer, switch or other pressure measuring instrument.

A: Diaphragm seals can be used with pressure gauges, pressure transducers and transmitters, and electronic pressure switches.

A: Cooling elements work in combination with diaphragm seals to isolate the instrument from high media temperatures and are recommended for process temperatures above 212 ∞F. They provide effective temperature reductions of up to 200 ∞F depending upon ambient conditions and require a direct mounted system. Stainless steel capillaries with or without stainless steel armor can be used to protect the instrument from high or low process temperatures and allow remote mounting of pressure instruments; the shortest practical capillary length should be selected, as changes in ambient temperature conditions may significantly affect accuracy and response time. Sanitary clamps and gaskets for the NOSHOK Type 12 seal are available in NBR, EPDM, PTFE and FKM and meet FDA and 3A sanitary standards.

A: In general, the diaphragm adds approximately one-half percent to the instrument error at room temperature. There are also additional thermal errors that need to be calculated depending on the application. NOSHOK provides a thermal error calculation document to support these calculations, such as the Diaphragm Seal Thermal Error Calculations PDF available on the NOSHOK website.

A: The fill fluid pressure is equal to the application pressure. If a diaphragm bursts, the fill fluid will be dispersed into the process media and the instrument will be subjected directly to the pressure of the process media.

More questions? Contact NOSHOK Customer Support at info@noshok.com

PT Transmitter Crossover Tool

Convert to PT Series